SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kramer Elissa L.)
 

Sökning: WFRF:(Kramer Elissa L.) > (1995-1999) > Tumor localization ...

Tumor localization and image registration of 18-FDG SPECT scans with CT scans

Aitken, Candice L. (författare)
New York University
McGuinness, Georgeann (författare)
New York University
Siddiqui, Faaiza (författare)
New York University
visa fler...
Ton, Anthony (författare)
New York University
Kramer, Elissa L (författare)
New York University
Maguire Jr., Gerald Q. (författare)
KTH,Teleinformatik
Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
visa färre...
 (creator_code:org_t)
Society of Nuclear Medicine, 1999
1999
Engelska.
Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 40:5, s. 290P-291P
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The aim of this study was to determine the feasibility of registering routine clinical F-18 fluorodeoxyglucose (FDG) coincidence detection (CD) scans with computed tomographic (CT) scans for radiation treatment planning and case management. METHODS: F-18 FDG CD and chest CT scans, performed in 10 randomly selected patients with confirmed or possible adenocarcinoma of the lung, were evaluated. The quality of the matches was verified by comparisons of the center-to-center distance between a region of interest (ROI) manually drawn on the CT slice and warped onto the CD slice with an ROI drawn manually directly on the CD slice. In addition, the overlap between the two ROIs was calculated. RESULTS: All 10 F-18 FDG CD and CT scans were registered with good superimposition of soft tissue density on increased radionuclide activity. The center-to-center distance between the ROIs ranged from 0.29 mm to 8.08 mm, with an average center-to-center distance of 3.89 mm +/- 2.42 mm (0.69 pixels +/- 0.34 pixels). The ROI overlap ranged from 77% to 99%, with an average of 90% +/- 5.6%. CONCLUSIONS: Although the use of F-18 FDG CD shows great promise for the identification of tumors, it shares the same drawbacks as those associated with radiolabeled monoclonal antibody SPECT and ligand-based positron emission tomographic scans in that anatomic markers are limited. This study shows that image registration is feasible and may improve the clinical relevance of CD images.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy