SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Elektroteknik och elektronik)
 

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Elektroteknik och elektronik) > (2010-2019) > Fault Detection and...

Fault Detection and Localization for Limp Home Functionality of Three-Level NPC Inverters with Connected Neutral Point for Electric Vehicles

Kersten, Anton, 1991 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Oberdieck, Karl (författare)
Rheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University
Bubert, Andreas (författare)
Rheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University
visa fler...
Neubert, Markus (författare)
Rheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University
Grunditz, Emma, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Thiringer, Torbjörn, 1966 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
De Doncker, Rik W. (författare)
Rheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University
visa färre...
 (creator_code:org_t)
2019
2019
Engelska.
Ingår i: IEEE Transactions on Transportation Electrification. - 2332-7782. ; 5:2, s. 416-432
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper deals with the detection of single battery or inverter switch faults during operation of a common and an active three-level neutral-point-clamped (NPC) inverter with a connected neutral point. Here, the main focus lies on the detection and localization of open-circuit faults of the inverter's switches. Therefore, a fault detection algorithm, using a current estimator, and two fault localization algorithms, a pulse pattern injection principle and an online adaption of the space vector modulation (SVM), are investigated and verified through simulations and experiments. Also, investigated is how the powertrain can be operated under a fault condition, so that the vehicle can drive with a limited maximum power using an adapted SVM, referred to as "limp home" mode, to the next service station. It is shown, that an active NPC inverter can cope with any single short or open-circuit fault of the inverter's switches without bringing the vehicle to standstill, whereas a generic NPC inverter loses controllability if an open-circuit fault at an inner switch occurs. Furthermore, both inverter types are able to be operated just with half of the dc-link voltage in case of a failure in one part of the battery.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Farkostteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Vehicle Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

fault tolerance
multilevel systems
Fault location
neutral point clamped (NPC)
vehicles
redundancy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy