SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thottappillil Rajeev 1958 )
 

Sökning: WFRF:(Thottappillil Rajeev 1958 ) > Investigating the v...

  • Liu, YaqingUppsala universitet,Elektricitetslära och åskforskning (författare)

Investigating the validity of existing definitions and empirical equations of effective length/area of grounding wire/grid for transient studies

  • Artikel/kapitelEngelska2007

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2007
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-62557
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-62557URI
  • https://doi.org/10.1016/j.elstat.2006.09.005DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-14000URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20120221
  • There are various definitions for effective length/area of grounding wire/grid for lightning transients [A.S. Farag, T.C. Cheng, D. Penn, Grounding terminations of lightning protective systems, IEEE Trans. Dielectics, Elect. Insul 5(6) (1998) 869-877; B.R. Gupta, B. Thapar, Impulse impedance of grounding grid, IEEE Trans. Power Apparatus Syayem PAS-99(6) (1980) 2357-2362; Y. Liu, N. Theethayi, R. Thottappillil, An engineering model for transient analysis of grounding system under lightning strikes: non-uniform transmission line approach. IEEE Trans. Power Delivery 20 (2) (2005) 722-730; M.I. Lorentzou, N.D. Hatziargriou, Modelling of long grounding conductors using EMTP, in: IPST'99, International Conference on Power System Transients, Budapest, 20-24 June, 1999; L.D. Grcev, M. Heimbach, Frequency dependent and transient characteristics of substation grounding system, IEEE Trans. Power Delivery 12 (1997) 172-178.]. The present work investigates and discusses the validity of those existing definitions. Further, practical methods for estimating the effective length/area of different grounding structures are proposed for engineering applications. The calculations for effective length/area based on non-uniform transmission line approach (Liu et al., 2005) show that, for a single grounding wire, the empirical equation for effective length in Farag et al. (1998) is not valid when the injection current has very fast rise time. Also, the empirical equation for effective length of grid edge in Gupta and Thapar (1980) is not applicable for grids with large inner mesh size.

Ämnesord och genrebeteckningar

  • lightning
  • grounding wire and grid
  • effective length and lightning transient
  • TECHNOLOGY

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Theethayi, NelsonUppsala universitet,Elektricitetslära och åskforskning,Elektricitetslära(Swepub:uu)nethe133 (författare)
  • Thottappillil, Rajeev,1958-Uppsala universitet,Elektricitetslära och åskforskning,Elektricitetslära(Swepub:uu)rajethot (författare)
  • Uppsala universitetElektricitetslära och åskforskning (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Electrostatics: Elsevier BV65:5-6, s. 329-3350304-38861873-5738

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy