SwePub
Sök i LIBRIS databas

  Utökad sökning

LAR1:hig
 

Sökning: LAR1:hig > (2005-2009) > Detailed CFD modell...

Detailed CFD modelling of EMC screen for radio base stations : a parametric study

Anton Remirez, Raul (författare)
Högskolan i Gävle,KTH,Energiteknik,Ämnesavdelningen för energi- och maskinteknik,Department of Mechanical Engineering, TECNUN, University of Navarra, Navarra, Spain; Division of Applied Thermodynamics and Refrigeration, KTH Energy Technology, Royal Institute of Technology, Stockholm, Sweden
Jonsson, Hans (författare)
Högskolan i Gävle,KTH,Energiteknik,Ämnesavdelningen för energi- och maskinteknik,Division of Applied Thermodynamics and Refrigeration, KTH Energy Technology, Royal Institute of Technology, Stockholm, Sweden
Moshfegh, Bahram (författare)
Högskolan i Gävle,Ämnesavdelningen för energi- och maskinteknik
 (creator_code:org_t)
2009
2009
Engelska.
Ingår i: IEEE transactions on components and packaging technologies (Print). - 1521-3331 .- 1557-9972. ; 32:1, s. 145-155
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objective of this paper is to make a parametric study of the hydraulic resistance and flow pattern of the flow after an electromagnetic compatibility screen and between two printed circuit boards (PCBs) in a model of a 90° subrack cooling architecture. The parametric study is carried out using a detailed 3-D model of a PCB slot. The detailed model was experimentally validated in a previous paper by the authors. Seven parameters were investigated: velocity, inlet height, screen porosity, PCB thickness, distance between two PCBs, inlet-screen gap and screen thickness. A correlation for the static anddynamic pressure drop, the percentage of dimensionless wetted area, Aw*, and the RMS* factor (a function of the flow uniformity along the PCB) after the screen is reported as a function of six geometrical dimensionless parameters and the Reynolds number. The correlations, that are based on 174 three dimensional simulations, yield good results for the total pressure drop, in which the values are predicted within the interval of ±15%. For the, Aw* all the predicted values are within the interval of ±22% of the observed values. Finally, for the RMS* factor, the majority of the values also have a disagreement of less than 20% of the observed values. These last two parameters are believed to provide a correct insight about the flow pattern after the screen.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Electromagnetic compatibility (EMC) screen
Flow pattern
K-ε
Perforated plate
Porosity
Pressure drop
Renormalization group (RNG)
Subrack
Wetted area
Mechanical energy engineering
Mekanisk energiteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy