Sökning: L773:1076 5174 OR L773:1096 9888 > Influence of drople...

Influence of droplet size, capillary-cone distance and selected instrumental parameters for the analysis of noncovalent protein-ligand complexes by nano-electrospray ionization mass spectrometry

Benkestock, Kurt (författare)
KTH,Kemi
Sundqvist, Gustav (författare)
KTH,Kemi
Edlund, Per Olof (författare)
Biovitrum AB, Dept Analyt Sci
visa fler...
Roeraade, Johan (författare)
KTH,Kemi
visa färre...
 (creator_code:org_t)
2004-09-24
2004
Engelska.
Ingår i: Journal of Mass Spectrometry. - : Wiley. - 1076-5174 .- 1096-9888. ; 39:9, s. 1059-1067
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • It has been suggested in the literature that nano-electrospray ionization (nano-ESI) mass spectrometry better reflects the equilibrium between complex and free protein in solution than pneumatically assisted electrospray ionization (ESI) in noncovalent interaction studies. However, no systematic studies of the effects of ionization conditions have been performed to support this statement. In the present work, different instrumental and sample-derived parameters affecting the stability of noncovalent complexes during analysis by nano-ESI were investigated. In general, increased values of parameters such as drying gas flow-rate, ion-source temperature, capillary tip voltage and buffer concentration lead to a dissociation of ribonuclease A (RNAse)-cytidine 2'-monophosphate (CMP) and cytidine 5'-triphosphate (CTP) complexes. The size of the electrosprayed droplets was shown to be an important issue. Increasing the capillary to cone distance yielded an increased complex to free protein ratio when a hydrophilic ligand was present and the reverse effect was obtained with a hydrophobic ligand. Important in this regard is the degree of sampling of ions originating from late-generation residue droplets, that is, ions present in the droplet bulk. Sampling of these ions increases with longer capillary-cone distance (flight time). Furthermore, when the sample flow-rate was increased by increasing the capillary internal tip i.d. from 4 to 30 mum, a decreased complex to free protein ratio for the RNAse-CTP system was observed. This behavior was consistent with the change in surface to volume ratio for flow-rates between 2 and 100 nl min(-1). Finally, polarity switching between positive and negative ion modes gave a higher complex to free protein ratio when the ligand and the protein had the same polarity.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

nano-electrospray ionization; noncovalent complexes; droplet size; capillary-cone distance; H-FABP; RNAse; BINDING INTERACTIONS; QUANTITATIVE-DETERMINATION; COMPETITIVE-BINDING; RESOLUTION; RECEPTOR; CHARGE; DNA
Analytical chemistry
Analytisk kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Benkestock, Kurt
Sundqvist, Gusta ...
Edlund, Per Olof
Roeraade, Johan
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Journal of Mass ...
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.