SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Schönberg Tommy)
 

Sökning: WFRF:(Schönberg Tommy) > (2009) > Electrospray Ioniza...

  • Ek, PatrikKTH,Analytisk kemi (författare)

Electrospray Ionization from an Adjustable Gap between two Silicon Chips

  • Artikel/kapitelEngelska2009

Förlag, utgivningsår, omfång ...

  • Wiley,2009
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-8438
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-8438URI
  • https://doi.org/10.1002/jms.1478DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20100913. Uppdaterad från Manuskript till Artikel (20100913)
  • In this paper, a silicon chip - based electrospray emitter with a variable orifice size is presented. The device consists of two chips, with a thin beam elevating from the center of each of the chips. The chips are individually mounted to form an open gap of a narrow, uniform width between the top areas of the beams. The electrospray is generated at the endpoint of the gap, where the spray point is formed by the very sharp intersection between the crystal planes of the < 100 > silicon chips. Sample solution is applied to the rear end of the gap from a capillary via a liquid bridge, and capillary forces ensure a spontaneous imbibition of the gap. The sample solution is confined to the gap by means of a hydrophobic treatment of the surfaces surrounding the gap, as well as the geometrical boundaries formed by the edges of the gap walls. The gap width could be adjusted between 1 and 25 μm during electrospray experiments without suffering from any interruption of the electrospray process. Using a peptide sample solution, a shift toward higher charge states and increased signal-to-noise ratios was observed when the gap width was decreased. The limit of detection for the peptide insulin (chain B, oxidized) was approximately 4 nM. We also show a successful interfacing of the electrospray setup with capillary electrophoresis.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Schönberg, Tommy (författare)
  • Sjödahl, JohanKTH,Analytisk kemi(Swepub:kth)u1x6yql8 (författare)
  • Jacksén, JohanKTH,Analytisk kemi(Swepub:kth)u16m794h (författare)
  • Vieider, Christian (författare)
  • Emmer, ÅsaKTH,Analytisk kemi(Swepub:kth)u1czoysx (författare)
  • Roeraade, JohanKTH,Analytisk kemi(Swepub:kth)u10i2qgl (författare)
  • KTHAnalytisk kemi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Mass Spectrometry: Wiley44:2, s. 171-1811076-51741096-9888

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy