SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Herndon M.))
 

Sökning: (WFRF:(Herndon M.)) > (2005-2009) > Microfluidic leukoc...

Microfluidic leukocyte isolation for gene expression analysis in critically ill hospitalized patients

Russom, Aman (författare)
Surgical Services and Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School and Shriners Hospital for Children, Boston
Sethu, Palaniappan (författare)
Irimia, Daniel (författare)
visa fler...
Mindrinos, Michael N. (författare)
Calvan, Steve E. (författare)
Garcia, Iris (författare)
Finnerty, Celeste (författare)
Tannahill, Cynthia (författare)
Abouhamze, Amer (författare)
Wilhelmy, Julie (författare)
Lopez, M. Cecilia (författare)
Baker, Henry V. (författare)
Herndon, David N. (författare)
Lowry, Stephen F. (författare)
Maier, Ronald V. (författare)
Davis, Ronald W. (författare)
Moldawer, Lyle L. (författare)
Tompkins, Ronald G. (författare)
Toner, Mehmet (författare)
visa färre...
 (creator_code:org_t)
2008-05-01
2008
Engelska.
Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:5, s. 891-900
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Microarray technology is becoming a powerful tool for diagnostic, therapeutic, and prognostic applications. There is at present no consensus regarding the optimal technique to isolate nucleic acids from blood leukocyte populations for subsequent expression analyses. Current collection and processing techniques pose significant challenges in the clinical setting. Here, we report the clinical validation of a novel microfluidic leukocyte nucleic acid isolation technique for gene expression analysis from critically ill, hospitalized patients that can be readily used on small volumes of blood. METHODS: We processed whole blood from hospitalized patients after burn injury and severe blunt trauma according to the microfluidic and standard macroscale leukocyte isolation protocol. Side-by-side comparison of RNA quantity, quality, and genome-wide expression patterns was used to clinically validate the microfluidic technique. RESULTS: When the microfluidic protocol was used for processing, sufficient amounts of total RNA were obtained for genome-wide expression analysis from 0.5 mL whole blood. We found that the leukocyte expression patterns from samples processed using the 2 protocols were concordant, and there was less variability introduced as a result of harvesting method than there existed between individuals. CONCLUSIONS: The novel microfluidic approach achieves leukocyte isolation in <25 min, and the quality of nucleic acids and genome expression analysis is equivalent to or surpasses that obtained from macroscale approaches. Microfluidics can significantly improve the isolation of blood leukocytes for genomic analyses in the clinical setting. (c) 2008 American Association for Clinical Chemistry.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy