X-ray phase contrast for CO2 microangiography

Lundström, Ulf (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Larsson, Daniel H. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Burvall, Anna (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa fler...
Takman, Per A. C. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
Scott, L. (författare)
Karolinska Institutet
Brismar, H. (författare)
Karolinska Institutet
Hertz, Hans M. (författare)
KTH,Biomedicinsk fysik och röntgenfysik
visa färre...
 (creator_code:org_t)
2012-04-13
2012
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 57:9, s. 2603-2617
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We demonstrate a laboratory method for imaging small blood vessels using x-ray propagation-based phase-contrast imaging and carbon dioxide (CO2) gas as a contrast agent. The limited radiation dose in combination with CO2 being clinically acceptable makes the method promising for small-diameter vascular visualization. We investigate the possibilities and limitations of the method for small-animal angiography and compare it with conventional absorption-based x-ray angiography. Photon noise in absorption-contrast imaging prevents visualization of blood vessels narrower than 50 mu m at the highest radiation doses compatible with living animals, whereas our simulations and experiments indicate the possibility of visualizing 20 mu m vessels at radiation doses as low as 100 mGy. Experimental computed tomography of excised rat kidney shows blood vessels of diameters down to 60 mu m with improved image quality compared to absorption-based methods. With our present prototype x-ray source, the acquisition time for a tomographic dataset is approximately 1 h, which is long compared to the 1-20 min common for absorption-contrast micro-CT systems. Further development of the liquid-metal-jet microfocus x-ray sources used here and high-resolution x-ray detectors shows promise to reduce exposure times and make this high-resolution method practical for imaging of living animals.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Angiography
Blood vessels
Carbon dioxide
Dosimetry
Image quality
Imaging techniques
Visualization
X ray apparatus
X rays

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy