SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-101061"
 

Sökning: id:"swepub:oai:DiVA.org:liu-101061" > A digital heterodyn...

  • Jacob, StefanKarolinska Institutet (författare)

A digital heterodyne laser interferometer for studying cochlear mechanics

  • Artikel/kapitelEngelska2009

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2009
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-101061
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-101061URI
  • https://doi.org/10.1016/j.jneumeth.2009.02.002DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:118691194URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Laser interferometry is the technique of choice for studying the smallest displacements of the hearing organ. For low intensity sound stimulation, these displacements may be below 1 nm. This cannot be reliably measured with other presently available techniques in an intact organ of Corti. In a heterodyne interferometer, light is projected against an object of study and motion of the target along the optical axis causes phase and frequency modulations of the back-reflected light. To recover object motion, the reflected light is made to interfere with a reference beam of artificially altered frequency, producing a beating signal. In conventional interferometers, this carrier signal is demodulated with analog electronics. In this paper, we describe a digital implementation of the technique, using direct carrier sampling. In order to obtain the necessary reference signal for demodulation we introduce an additional third light path. Together, this results in lower noise and reduces the cost of the system.Within the hearing organ, different structures may move in different directions. It is therefore necessary to precisely measure the angle of incidence of the laser light, and to precisely localize the anatomical structure where the measurement is performed. Therefore, the interferometer is integrated with a laser scanning confocal microscope that permits us to map crucial morphometric parameters in each experiment. We provide key construction parameters and a detailed performance characterization. We also show that the system accurately measures the diminutive vibrations present in the apical turn of the cochlea during low-level sound stimulation.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Johansson, Cecilia (författare)
  • Ulfendahl, MatsKarolinska Institutet (författare)
  • Fridberger, Anders,1966-Karolinska Institutet(Swepub:liu)andfr39 (författare)
  • Karolinska Institutet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Neuroscience Methods: Elsevier BV179:2, s. 271-2770165-02701872-678X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy