Estimations of effective dose in X-ray examinations derived from information stored in PACS

Gårdestig, Magnus, 1973- (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Helmrot, Ebba (författare)
Linköpings universitet,Medicinsk radiologi,Hälsouniversitetet,Jönköping County Hospital
Sandborg, Michael (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
visa fler...
Nilsson Althén, Jonas (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Bahar Gogani, Jalil (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Alm Carlsson, Gudrun (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Pettersson, Håkan BL (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Stockholm : Statens Strålskyddsinstitut, 2005
2005
Engelska.
Ingår i: Radiological Protection in Transition. - Stockholm : Statens Strålskyddsinstitut. ; , s. 175-178
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Information about each X-ray examination, in a modern digitized X-ray department is generated and stored in a PACS. Appropriate conversion factors, e.g. E/DAP, can be applied to separate projections and summed to the total effective dose for each examination. The objectives of the work were (i) to investigate the accuracy and precision in the calculated effective dose (ii) to identify data for registration of (1) patient dose, (2) exposure data, and (3) patient information (iii) to make it possible to derive dose statistics on patient level for documentation of diagnostic standard doses, optimizations, constancy checks, and future epidemiological studies. The effective doses were calculated using Monte Carlo based computer programs or by using tabulations. Conversion factors were calculated for different levels of information and the individual effective dose was compared to the most precise estimation. The results suggest that the accuracy in the estimations of effective dose increases by added information about the patient (gender, size) and how the examination was performed.

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy