SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Berlin Gösta)
 

Sökning: WFRF:(Berlin Gösta) > (2010-2014) > In vitro properties...

In vitro properties of platelets stored in a small container for pediatric transfusion

Tynngård, Nahreen (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för inflammationsmedicin,Hälsouniversitetet,Klinisk immunologi och transfusionsmedicin,Klinisk kemi
Trinks, Marie (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för inflammationsmedicin,Hälsouniversitetet,Klinisk immunologi och transfusionsmedicin
Berlin, Gösta (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för inflammationsmedicin,Hälsouniversitetet,Klinisk immunologi och transfusionsmedicin
 (creator_code:org_t)
2013-11-14
2014
Engelska.
Ingår i: Transfusion. - : Wiley-Blackwell. - 0041-1132 .- 1537-2995. ; 54:6, s. 1562-1568
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND:The quality of a platelet (PLT) concentrate (PC) is affected by the number of PLTs in relation to the size and gas permeability of the container. This study evaluates the in vitro function, including hemostatic properties (clot formation and elasticity), of PLTs stored in a container of standard or small size.STUDY DESIGN AND METHODS:PCs with 30% plasma and 70% PLT additive solution were prepared from buffy coats. Two PCs were pooled and divided into the following containers: 1 unit and ½ a unit into a 1.8-L container (reference container) and ½ a unit into a 0.45-L container (test container). In a second set of experiments ¼ of a unit was stored in the reference and test containers. Swirling, PLT count, blood gases, metabolic variables, PLT activation markers, hypotonic shock response (HSR), and coagulation by free oscillation rheometry were analyzed during 7 days of storage.RESULTS:Swirling was well preserved and pH was acceptable (6.4-7.4) during storage of PLTs in both containers. Glycolysis and PLT activation were higher when storing ½ and ¼ of a unit in the reference container and storage of ¼ of a unit in the reference container resulted in the largest decrease in HSR. The clotting time was similar whereas the clot elasticity was slightly lower for PLTs when stored as ½ and ¼ of a unit in the reference container.CONCLUSION:Storage of a low number of PLTs benefits by storage in a small container in terms of better maintained in vitro properties.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Tynngård, Nahree ...
Trinks, Marie
Berlin, Gösta
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
Artiklar i publikationen
Transfusion
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy