SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nishimura Takashi)
 

Sökning: WFRF:(Nishimura Takashi) > Less frequent openi...

Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device

Hatano, Masaru (författare)
University of Tokyo, Japan
Kinugawa, Koichiro (författare)
University of Tokyo, Japan
Shiga, Taro (författare)
University of Tokyo, Japan
visa fler...
Kato, Naoko (författare)
University of Tokyo, Japan
Endo, Miyoko (författare)
University of Tokyo, Japan
Hisagi, Motoyuki (författare)
University of Tokyo, Japan
Nishimura, Takashi (författare)
University of Tokyo, Japan
Yao, Atsushi (författare)
University of Tokyo, Japan
Hirata, Yasunobu (författare)
University of Tokyo, Japan
Kyo, Shunei (författare)
University of Tokyo, Japan
Ono, Minoru (författare)
University of Tokyo, Japan
Nagai, Ryozo (författare)
University of Tokyo, Japan
visa färre...
 (creator_code:org_t)
Japanese Circulation Society, 2011
2011
Engelska.
Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 75:5, s. 1147-1155
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND:Postoperative development of aortic insufficiency (AI) after implantation of left ventricular assist devices (LVADs) has recently been recognized, but the devices in the previous reports have been limited to the HeartMate I or II. The purposes of this study were to determine whether AI develops with other types of LVADs and to elucidate the factors associated with the development of AI.METHODS AND RESULTS:Thirty-seven patients receiving LVADs without evident abnormalities in native aortic valves were enrolled (pulsatile flow LVAD [TOYOBO]: 76%, continuous flow LVAD [EVAHEART, DuraHeart, Jarvik2000, HeartMate II]: 24%). Frequency of aortic valve opening and grade of AI were evaluated by the most recent echocardiography during LVAD support. None of the patients had more than trace AI preoperatively. During LVAD support AI >- grade 2 developed in 9 patients (24%) across all 5 types of devices. More severe grade of AI correlated with higher plasma B-type natriuretic peptide concentration (r = 0.53, P < 0.01) and with less frequent of the aortic valve (r = 0.45, P < 0.01). Multivariate analysis revealed that lower preoperative left ventricular ejection fraction and a continuous flow device type were independent risk factors for higher incidence of AI.CONCLUSIONS:AI, which is hemodynamically significant, develops after implantation of various types of LVADs. Physicians need to be more alert to the development of AI particularly with continuous flow devices.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Nyckelord

Aortic insufficiency; Heart failure; Left ventricular assist device; Transplantation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy