Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device
-
- Hatano, Masaru (författare)
- University of Tokyo, Japan
-
- Kinugawa, Koichiro (författare)
- University of Tokyo, Japan
-
- Shiga, Taro (författare)
- University of Tokyo, Japan
-
visa fler...
-
- Kato, Naoko (författare)
- University of Tokyo, Japan
-
- Endo, Miyoko (författare)
- University of Tokyo, Japan
-
- Hisagi, Motoyuki (författare)
- University of Tokyo, Japan
-
- Nishimura, Takashi (författare)
- University of Tokyo, Japan
-
- Yao, Atsushi (författare)
- University of Tokyo, Japan
-
- Hirata, Yasunobu (författare)
- University of Tokyo, Japan
-
- Kyo, Shunei (författare)
- University of Tokyo, Japan
-
- Ono, Minoru (författare)
- University of Tokyo, Japan
-
- Nagai, Ryozo (författare)
- University of Tokyo, Japan
-
visa färre...
-
(creator_code:org_t)
- Japanese Circulation Society, 2011
- 2011
- Engelska.
-
Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 75:5, s. 1147-1155
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND:Postoperative development of aortic insufficiency (AI) after implantation of left ventricular assist devices (LVADs) has recently been recognized, but the devices in the previous reports have been limited to the HeartMate I or II. The purposes of this study were to determine whether AI develops with other types of LVADs and to elucidate the factors associated with the development of AI.METHODS AND RESULTS:Thirty-seven patients receiving LVADs without evident abnormalities in native aortic valves were enrolled (pulsatile flow LVAD [TOYOBO]: 76%, continuous flow LVAD [EVAHEART, DuraHeart, Jarvik2000, HeartMate II]: 24%). Frequency of aortic valve opening and grade of AI were evaluated by the most recent echocardiography during LVAD support. None of the patients had more than trace AI preoperatively. During LVAD support AI >- grade 2 developed in 9 patients (24%) across all 5 types of devices. More severe grade of AI correlated with higher plasma B-type natriuretic peptide concentration (r = 0.53, P < 0.01) and with less frequent of the aortic valve (r = 0.45, P < 0.01). Multivariate analysis revealed that lower preoperative left ventricular ejection fraction and a continuous flow device type were independent risk factors for higher incidence of AI.CONCLUSIONS:AI, which is hemodynamically significant, develops after implantation of various types of LVADs. Physicians need to be more alert to the development of AI particularly with continuous flow devices.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences (hsv//eng)
Nyckelord
- Aortic insufficiency; Heart failure; Left ventricular assist device; Transplantation
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Hatano, Masaru
-
Kinugawa, Koichi ...
-
Shiga, Taro
-
Kato, Naoko
-
Endo, Miyoko
-
Hisagi, Motoyuki
-
visa fler...
-
Nishimura, Takas ...
-
Yao, Atsushi
-
Hirata, Yasunobu
-
Kyo, Shunei
-
Ono, Minoru
-
Nagai, Ryozo
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Hälsovetenskap
- Artiklar i publikationen
-
Circulation Jour ...
- Av lärosätet
-
Linköpings universitet