SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hole K.)
 

Sökning: WFRF:(Hole K.) > (2010-2014) > EPR dosimetry inter...

EPR dosimetry intercomparison using smart phone touch screen glass

Fattibene, Paola (författare)
Istituto Superiore di Sanità, Rome, Italy
Trompier, Francois (författare)
Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
Wieser, Albrecht (författare)
Institute of Radiation Protection, Helmholtz Zentrum München - German Research Center for Environmental Health, Neuherberg, Germany
visa fler...
Brai, Maria (författare)
Dipartimento di Fisica e Chimica, Università di Palermo, Viale Delle Scienze, Palermo, Italy
Ciesielski, Bartlomej (författare)
Medical University of Gdansk, Gdańsk, Poland
De Angelis, Cinzia (författare)
Istituto Superiore di Sanità, Rome, Italy
Della Monaca, Sara (författare)
Istituto Superiore di Sanità, Rome, Italy
Garcia, Tristan (författare)
CEA, LIST, Laboratoire National Henri Becquerel, Gif-sur-Yvette, France
Gustafsson, Håkan (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet,Medicinsk teknik i Östergötland
Hole, Eli Olag (författare)
Department of Physics, University of Oslo (UiO), Oslo, Norway
Juniewicz, M. (författare)
Medical University of Gdansk, Gdańsk, Poland
Krefft, K. (författare)
Medical University of Gdansk, Gdańsk, Poland
Longo, Anna (författare)
Dipartimento di Fisica e Chimica, Università di Palermo, Palermo, Italy
Leveque, Philippe (författare)
Université Catholique de Louvain, Louvain, Belgium
Lund, Eva (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet
Marrale, Maurizio (författare)
Dipartimento di Fisica e Chimica, Università di Palermo, Palermo, Italy
Michalec, Barbara (författare)
The Henryk Niewodniczański Institute of Nuclear Physics, Kraków, Poland
Mierzwinska, Gabriela (författare)
The Henryk Niewodniczański Institute of Nuclear Physics, Kraków, Poland
Rao, J. L. (författare)
Sri Venkateswara University, Tirupati, Andhra Pradesh, India
Romanyukha, Alexander A. (författare)
Naval Dosimetry Center, US Navy, Bethesda, MD, USA
Tuner, Hasan (författare)
Department of Physics, Faculty of Art and Science, Balikesir University, 10145, Cagis, Balıkesir, Turkey
visa färre...
 (creator_code:org_t)
2014-03-27
2014
Engelska.
Ingår i: Radiation and Environmental Biophysics. - : Springer-Verlag New York. - 0301-634X .- 1432-2099. ; 53:2, s. 311-320
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogeneous batch of glass and were stored in similar setting; for group B (formed by eight participants), samples came from different smart phones and stored in different settings of light and temperature. The calibration curves determined by the participants of group A had a small error and a critical level in the 0.37-0.40-Gy dose range, whereas the curves determined by the participants of group B were more scattered and led to a critical level in the 1.3-3.2-Gy dose range for six participants out of eight. Group A were able to assess the dose within 20 % for the lowest doses (< 1.5 Gy) and within 5 % for the highest doses. For group B, only the highest blind dose could be evaluated in a reliable way because of the high critical values involved. The results from group A are encouraging, whereas the results from group B suggest that the influence of environmental conditions and the intervariability of samples coming from different smart phones need to be further investigated. An alongside conclusion is that the protocol was easily transferred to participants making a network of laboratories in case of a mass casualty event potentially feasible.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

EPR dosimetry
Radiological emergency
Retrospective dosimetry
Glass

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy