SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:liu-115147"
 

Search: id:"swepub:oai:DiVA.org:liu-115147" > An Optical Method f...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Holmar, JanaTallin University of Technology, Tallin, Estonia (author)

An Optical Method for Serum Calcium and Phosphorus Level Assessment during Hemodialysis

  • Article/chapterEnglish2015

Publisher, publication year, extent ...

  • 2015-02-27
  • BASEL, SWITZERLAND :MDPI AG,2015
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-115147
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-115147URI
  • https://doi.org/10.3390/toxins7030719DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • The research was funded partly by the County Council of Ostergotland, Sweden, Estonian Science Foundation Grant No. 8621, Estonian Ministry of Education and Research under institutional research financing IUT 19-2 and the European Union through the European Regional Development Fund.
  • Survival among hemodialysis patients is disturbingly low, partly because vascular calcification (VC) and cardiovascular disease are highly prevalent. Elevated serum phosphorus (P) and calcium (Ca) levels play an essential role in the formation of VC events. The purpose of the current study was to reveal optical monitoring possibilities of serum P and Ca values during dialysis. Twenty-eight patients from Tallinn (Estonia) and Linköping (Sweden) were included in the study. The serum levels of Ca and P on the basis of optical information, i.e., absorbance and fluorescence of the spent dialysate (optical method) were assessed. Obtained levels were compared in means and SD. The mean serum level of Ca was 2.54 ± 0.21 and 2.53 ± 0.19 mmol/L; P levels varied between 1.08 ± 0.51 and 1.08 ± 0.48 mmol/L, measured in the laboratory and estimated by the optical method respectively. The levels achieved were not significantly different (p = 0.5). The Bland-Altman 95% limits of agreement between the two methods varied from -0.19 to 0.19 for Ca and from -0.37 to 0.37 in the case of P. In conclusion, optical monitoring of the spent dialysate for assessing the serum levels of Ca and P during dialysis seems to be feasible and could offer valuable and continuous information to medical staff.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Uhlin, FredrikLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Njurmedicinska kliniken US(Swepub:liu)freuh89 (author)
  • Fernström, AndersLinköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, Njurmedicinska kliniken US(Swepub:liu)andfe39 (author)
  • Luman, MerikeTallin University of Technology, North Estonian Medical Centre, Tallin, Estonia (author)
  • Jankowski, JoachimAachen University , University Hospital Aachen, Germany (author)
  • Fridolin, IvoTallin University of Technology, Tallin, Estonia (author)
  • Tallin University of Technology, Tallin, EstoniaAvdelningen för kardiovaskulär medicin (creator_code:org_t)

Related titles

  • In:ToxinsBASEL, SWITZERLAND : MDPI AG7:3, s. 719-7272072-6651

Internet link

Find in a library

  • Toxins (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Holmar, Jana
Uhlin, Fredrik
Fernström, Ander ...
Luman, Merike
Jankowski, Joach ...
Fridolin, Ivo
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
and Health Care Serv ...
Articles in the publication
Toxins
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view