SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Schuetze Andreas)
 

Sökning: WFRF:(Schuetze Andreas) > Discrimination and ...

Discrimination and Quantification of Volatile Organic Compounds in the ppb-Range with Gas Sensitive SiC-FETs Using Multivariate Statistics

Bur, Christian (författare)
Linköpings universitet,Tillämpad sensorvetenskap,Tekniska fakulteten,Saarland University, Lab for Measurement Technology, Germany,Applied Sensor Science
Bastuk, Manuel (författare)
Saarland University, Lab for Measurement Technology, Germany
Puglisi, Donatella (författare)
Linköpings universitet,Tillämpad sensorvetenskap,Tekniska fakulteten,Applied Sensor Science
visa fler...
Schuetze, Andreas (författare)
Saarland University, Germany,Lab for Measurement Technology
Lloyd Spetz, Anita (författare)
Linköpings universitet,Tillämpad sensorvetenskap,Tekniska fakulteten,Applied Sensor Science
Andersson, Mike (författare)
Linköpings universitet,Tillämpad sensorvetenskap,Tekniska fakulteten,Applied Sensor Science
visa färre...
 (creator_code:org_t)
Elsevier, 2015
2015
Engelska.
Ingår i: Sensors and actuators. B, Chemical. - : Elsevier. - 0925-4005 .- 1873-3077. ; 214, s. 225-233
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Gas sensitive field effect transistors based on silicon carbide, SiC-FETs, have been studied for indoor air quality applications. The selectivity of the sensors was increased by temperature cycled operation, TCO, and data evaluation based on multivariate statistics. Discrimination of benzene, naphthalene, and formaldehyde independent of the level of background humidity is possible by using shape describing features as input for Linear Discriminant Analysis, LDA, or Partial Least Squares – Discriminant Analysis, PLS-DA. Leave-one-out cross-validation leads to a correct classification rate of 90 % for LDA, and for PLS-DA a classification rate of 83 % is achieved. Quantification of naphthalene in the relevant concentration range, i.e. 0 ppb to 40 ppb, was performed by Partial Least Squares Regression and a combination of LDA with a second order polynomial fit function. The resolution of the model based on a calibration with three concentrations was approximately 8 ppb at 40 ppb naphthalene for both algorithms.Hence, the suggested strategy is suitable for on demand ventilation control in indoor air quality application systems.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)

Nyckelord

Indoor Air Quality
temperature modulation
Linear Discriminant Analysis
Partial Least Squares
trace level detection

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy