Loss of local capture of the pulmonary vein myocardium after antral isolation : prevalence and clinical significance.

Squara, Fabien (författare)
Department of Cardiology, Pasteur University Hospital, Nice, France
Liuba, Ioan (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Chik, William (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
visa fler...
Santangeli, Pasquale (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Zado, Erica S (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Callans, David J (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
Marchlinski, Francis E (författare)
Electrophysiology Section, Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
visa färre...
 (creator_code:org_t)
2014-12-21
2015
Engelska.
Ingår i: Cardiovascular Electrophysiology. - : Wiley. - 1045-3873 .- 1540-8167. ; 26:3, s. 242-50
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION: Capture of the myocardial sleeves of the pulmonary veins (PV) during PV pacing is mandatory for assessing exit block after PV isolation (PVI). However, previous studies reported that a significant proportion of PVs failed to demonstrate local capture after PVI. We designed this study to evaluate the prevalence and the clinical significance of loss of PV capture after PVI.METHODS AND RESULTS: Thirty patients (14 redo) undergoing antral PVI were included. Before and after PVI, local PV capture was assessed during circumferential pacing (10 mA/2 milliseconds) with a circular multipolar catheter (CMC), using EGM analysis from each dipole of the CMC and from the ablation catheter placed in ipsilateral PV. Pacing output was varied to optimize identification of sleeve capture. All PVs demonstrated sleeve capture before PVI, but only 81% and 40% after first time and redo PVI, respectively (P < 0.001 vs. before PVI). In multivariate analysis, absence of spontaneous PV depolarizations after PVI and previous PVI procedures were associated with less PV sleeve capture after PVI (40% sleeve capture, P < 0.001 for both). Loss of PV local capture by design was coincident with the development of PV entrance block and importantly predicted absence of acute reconnection during adenosine challenge with 96% positive predictive value (23% negative predictive value).CONCLUSION: Loss of PV local capture is common after antral PVI resulting in entrance block, and may be used as a specific alternate endpoint for PV electrical isolation. Additionally, loss of PV local capture may identify PVs at very low risk of acute reconnection during adenosine challenge.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

ablation
atrial fibrillation
pulmonary veins
pulmonary vein isolation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy