SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Guitton T.G.)
 

Sökning: WFRF:(Guitton T.G.) > (2014) > Biomechanical studi...

Biomechanical studies: Science (f)or common sense?

Mellema, J.J. (författare)
Orthopaedic Hand and Upper Extremity Service, Massachusetts General Hospital, Harvard Medical SchoolBoston, MA, United States
Doornberg, J.N. (författare)
University of of Amsterdam Orthopaedic Residency Program (PGY 4), Academic Medical CenterAmsterdam, Netherlands
Guitton, T.G. (författare)
University of of Amsterdam Orthopaedic Residency Program (PGY 4), Academic Medical CenterAmsterdam, Netherlands
visa fler...
Ring, D. (författare)
Orthopaedic Hand and Upper Extremity Service, Massachusetts General Hospital, Harvard Medical SchoolBoston, MA, United States
visa färre...
 (creator_code:org_t)
Elsevier, 2014
2014
Engelska.
Ingår i: Injury. - : Elsevier. - 0020-1383 .- 1879-0267. ; 45:12, s. 2035-2039
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: It is our impression that many biomechanical studies invest substantial resources studying the obvious: that more and larger metal is stronger. The purpose of this study is to evaluate if a subset of biomechanical studies comparing fixation constructs just document common sense. Methods: Using a web-based survey, 274 orthopaedic surgeons and 81 medical students predicted the results of 11 biomechanical studies comparing fracture fixation constructs (selected based on the authors sense that the answer was obvious prior to performing the study). Sensitivity, specificity, and accuracy were calculated according to standard formulas. The agreement among the observers was calculated by using a multirater kappa, described by Siegel and Castellan. Results: The accuracy of predicting outcomes was 80% or greater for 10 of 11 studies. Accuracy was not influenced by level of experience (i.e., time in practice and medical students vs. surgeons). There were substantial differences in accuracy between observers from different regions. The overall categorical rating of inter-observer reliability according to Landis and Koch was moderate (k = 0.55; standard error (SE) = 0.01). Conclusion: The results of a subset of biomechanical studies comparing fracture fixation constructs can be predicted prior to doing the study. As these studies are time and resource intensive, one criterion for proceeding with a biomechanical study should be that the answer is not simply a matter of common sense. © 2014 Elsevier Ltd. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

Biomechanical; Fixation; Fracture; Orthopaedic

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Injury (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Mellema, J.J.
Doornberg, J.N.
Guitton, T.G.
Ring, D.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Injury
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy