Sökning: id:"swepub:oai:DiVA.org:liu-117725" >
Variability in echo...
-
de Geer, LinaLinköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, ANOPIVA US
(författare)
Variability in echocardiographic measurements of left ventricular function in septic shock patients
- Artikel/kapitelEngelska2015
Förlag, utgivningsår, omfång ...
-
2015-04-15
-
BioMed Central,2015
-
electronicrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:liu-117725
-
https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-117725URI
-
https://doi.org/10.1186/s12947-015-0015-6DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
BACKGROUND: Echocardiography is increasingly used for haemodynamic evaluation and titration of therapy in intensive care, warranting reliable and reproducible measurements. The aim of this study was to evaluate the observer dependence of echocardiographic findings of left ventricular (LV) diastolic and systolic dysfunction in patients with septic shock.METHODS: Echocardiograms performed in 47 adult patients admitted with septic shock to a general intensive care unit (ICU) were independently evaluated by one cardiologist and one intensivist for the following signs: decreased diastolic tissue velocity of the base of the LV septum (e), increased early mitral inflow (E) to e ratio (E/e), decreased LV ejection fraction (EF) and decreased LV global longitudinal peak strain (GLPS). Diastolic dysfunction was defined as e <8.0cm/s and/or E/e [greater than or equal to]15 and systolic dysfunction as EF <50% and/or GLPS>15%. Ten randomly selected examinations were re-analysed two months later. Pearson’s r was used to test the correlation and Bland-Altman plots to assess the agreement between observers. Kappa statistics were used to test the consistency between readers and intraclass correlation coefficients (ICC) for inter- and intraobserver variability.RESULTS: In 44 patients (94%), image quality was sufficient for echocardiographic measurements. The agreement between observers was moderate (k=0.60 for e, k=0.50 for E/e and k=0.60 for EF) to good (k=0.71 for GLPS). Pearson’s r was 0.76 for e, 0.85 for E/e, 0.78 for EF and 0.84 for GLPS (p<0.001 for all four). The ICC between observers for e was very good (0.85; 95% confidence interval (CI) 0.73-0.92), good for E/e (0.70; 95% CI 0.45 - 0.84), very good for EF (0.87; 95% CI 0.77 - 0.93), excellent for GLPS (0.91; 95% CI 0.74 - 0.95), and very good for all measures repeated by one of the observers. On Bland-Altman analysis, the mean differences and 95% limits of agreement for e, E/e, EF and GLPS were 0.01 (0.04 - 0.07), 2.0 (14.2 - 18.1), 0.86 (16 - 14.3) and 0.04 (5.04 - 5.12), respectively.CONCLUSIONS: Moderate observer-related differences in assessing LV dysfunction were seen. GLPS is the least user dependent and most reproducible echocardiographic measurement of LV function in septic shock.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Oscarsson, AnnaLinköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,Region Östergötland, ANOPIVA US(Swepub:liu)annos67
(författare)
-
Engvall, JanLinköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Region Östergötland, Fysiologiska kliniken US(Swepub:liu)janen74
(författare)
-
Linköpings universitetAvdelningen för läkemedelsforskning
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Cardiovascular Ultrasound: BioMed Central13:1, s. 19-1476-7120
Internetlänk
Hitta via bibliotek
Till lärosätets databas