SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Brundin Martin)
 

Sökning: WFRF:(Brundin Martin) > Validation of the p...

Validation of the paracetamol absorption test for measuring gastric tube emptying in esophagectomized patients versus gold standard scintigraphy

Djerf, Pauline (författare)
Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University, Sweden
Brundin, Martin, 1977 (författare)
Linköpings universitet,Medicinska fakulteten,Region Östergötland
Bajk, Marika (författare)
Lund University, Sweden
visa fler...
Smedh, Ulrika (författare)
Gothenburg University,Göteborgs universitet,Lund University,Lunds universitet,Kirurgi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Surgery (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,University of Gothenburg, Sweden,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
visa färre...
 (creator_code:org_t)
2015-06-16
2015
Engelska.
Ingår i: Scandinavian Journal of Gastroenterology. - : TAYLOR and FRANCIS LTD. - 0036-5521 .- 1502-7708. ; 50:11, s. 1339-1347
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. Scintigraphy is the gold standard for objective measurement of delayed gastric tube emptying after esophagectomy. The aim of this pilot study is to validate, by reference to scintigraphy, the paracetamol absorption test for measuring gastric tube emptying in esophagectomized patients. Material and methods. The paracetamol absorption test and scintigraphy were performed simultaneously in 13 patients who had undergone an esophagectomy with gastric tube reconstruction. Emptying was calculated for both methods and compared. Post-esophagectomy symptoms and quality of life (QoL) were assessed by European Organization on Research and Treatment of Cancer questionnaires. Results. Mean time to 50% emptying was 17 min measured with the paracetamol absorption test and 23 min with scintigraphy. For time to 25% emptying, Bland-Altman calculation gave a bias of 1.6 min and 95% limits of agreement (LoA) of -6.3 to 9.5 min. For time to 50% emptying, there was one outlier resulting in a bias of -6.33 min and 95% LoA of -36.4 to 23.8 min. For time to 75% emptying, bias was -11.6 min and 95% LoA of -38.5 to 15.4 min. Post-esophagectomy symptoms were similar to those reported previously, and QoL was comparable to the general Swedish population. Conclusions. There was reasonably close correlation between the paracetamol absorption test and scintigraphy for time to 25% and 50% emptying, except for one outlier. For time to 75% emptying the methods were in less accordance. The results indicate that the paracetamol absorption test may be a useful screening tool for identifying delayed gastric tube emptying in this patient group.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Gastroenterologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

esophagectomy; gastric emptying; paracetamol; scintigraphy; validation study

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy