SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sandberg Olof)
 

Sökning: WFRF:(Sandberg Olof) > Experimental models...

Experimental models for cancellous bone healing in the rat Comparison of drill holes and implanted screws

Bernhardsson, Magnus (författare)
Linköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten
Sandberg, Olof (författare)
Linköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten
Aspenberg, Per (författare)
Linköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten,Region Östergötland, Ortopedkliniken i Linköping
 (creator_code:org_t)
TAYLOR & FRANCIS LTD, 2015
2015
Engelska.
Ingår i: Acta Orthopaedica. - : TAYLOR & FRANCIS LTD. - 1745-3674 .- 1745-3682. ; 86:6, s. 745-750
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose - Cancellous bone appears to heal by mechanisms different from shaft fracture healing. There is a paucity of animal models for fractures in cancellous bone, especially with mechanical evaluation. One proposed model consists of a screw in the proximal tibia of rodents, evaluated by pull-out testing. We evaluated this model in rats by comparing it to the healing of empty drill holes, in order to explain its relevance for fracture healing in cancellous bone. To determine the sensitivity to external influences, we also compared the response to drugs that influence bone healing. Methods - Mechanical fixation of the screws was measured by pull-out test and related to the density of the new bone formed around similar, but radiolucent, PMMA screws. The pull-out force was also related to the bone density in drill holes at various time points, as measured by microCT. Results - The initial bone formation was similar in drill holes and around the screw, and appeared to be reflected by the pull-out force. Both models responded similarly to alendronate or teriparatide (PTH). Later, the models became different as the bone that initially filled the drill hole was resorbed to restore the bone marrow cavity, whereas on the implant surface a thin layer of bone remained, making it change gradually from a trauma-related model to an implant fixation model. Interpretation - The similar initial bone formation in the different models suggests that pull-out testing in the screw model is relevant for assessment of metaphyseal bone healing. The subsequent remodeling would not be of clinical relevance in either model.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bernhardsson, Ma ...
Sandberg, Olof
Aspenberg, Per
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Acta Orthopaedic ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy