Sökning: onr:"swepub:oai:DiVA.org:liu-126791" >
Citrate-selective e...
-
Azzouzi, SawsenUniversity of Sousse, Tunisia
(författare)
Citrate-selective electrochemical mu-sensor for early stage detection of prostate cancer
- Artikel/kapitelEngelska2016
Förlag, utgivningsår, omfång ...
-
ELSEVIER SCIENCE SA,2016
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:liu-126791
-
https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-126791URI
-
https://doi.org/10.1016/j.snb.2016.01.056DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Funding Agencies|NATO Science for Peace (SFP) Project [CBP.NUKR.SFP 984173]; FP7-PEOPLE-IRSES [318053]; SEA-on-a-Chip project [614168]
-
The extremely specialised anatomical function of citrate inside the prostate, make it one of the preferred biomarkers for early stage detection of prostate cancer. However, current detection methods are seriously limited due to the very low citrate concentrations that need to be measured in order to follow disease progression. In the present work, we report a novel citrate-selective-sensor based on iron (III) phthalocyanine chloride-C-monoamido-Poly-n-Butyl Acrylate (Fe(III)MAPcC1 P n BA) modified gold -electrodes for the electrochemical determination and estimation of the pathophysiological range of citrate. The newly synthesised ionophore has been structurally characterised using Fourier transform infrared (FTIR) and UV-vis spectroscopy. Contact angle measurements and atomic force microscopy (AFM) have been used to investigate the adhesion and morphological properties of the membrane. The developed citrate-selective-electrodes had a Nernstian sensitivity of-19.34 +/- 0.83 mV/decade with a detection limit of about 9 x 10-6M and a linear range from 4 x 10(-5)M to 10(-1) M, which covered the pathologically important clinical range. Electrochemical impedance spectroscopy (EIS) showed very high sensitivity with a lower Limit of detection 1.7 x 10(-9) M and linear detection range (10(-8)-10(-1) M), which is very important not only for the early-stage diagnosis and screening procedures, but also in mapping the stage of the cancer too. (C) 2016 Elsevier B.V. All rights reserved.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Patra, Hirak KumarLinköpings universitet,Avdelningen för cellbiologi,Medicinska fakulteten(Swepub:liu)hirpa77
(författare)
-
Ben Ali, MounirUniversity of Sousse, Tunisia
(författare)
-
Nooredeen Abbas, MohammedNational Research Centre, Egypt
(författare)
-
Dridi, CherifCentre Research Microelect and Nanotechnol CRMN Sousse, Tunisia
(författare)
-
Errachid, AbdelhamidUniversity of Lyon 1, France
(författare)
-
Turner, AnthonyLinköpings universitet,Biosensorer och bioelektronik,Tekniska fakulteten(Swepub:liu)anttu13
(författare)
-
University of Sousse, TunisiaAvdelningen för cellbiologi
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Sensors and actuators. B, Chemical: ELSEVIER SCIENCE SA228, s. 335-3460925-40051873-3077
Internetlänk
Hitta via bibliotek
Till lärosätets databas