SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:liu-126831"
 

Search: id:"swepub:oai:DiVA.org:liu-126831" > Quantification of t...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Petersson, SvenLinköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinska fakulteten,Avdelningen för kardiovaskulär medicin (author)

Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI

  • Article/chapterEnglish2016

Publisher, publication year, extent ...

  • WILEY-BLACKWELL,2016
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-126831
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-126831URI
  • https://doi.org/10.1002/mrm.25698DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:133098338URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Funding Agencies|European Research Council [310612]; Swedish Research Council; Swedish e-Science Research Centre
  • PurposeEvaluate spiral three-dimensional (3D) phase contrast MRI for the assessment of turbulence and velocity in stenotic flow. MethodsA-stack-of-spirals 3D phase contrast MRI sequence was evaluated in vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientations and flow rates. Volume flow rate, maximum velocity and turbulent kinetic energy (TKE) were computed for both methods. Moreover, the estimated TKE was compared with computational fluid dynamics (CFD) data. ResultsThere was good agreement between the turbulent kinetic energy from the spiral, Cartesian and CFD data. Flow rate and maximum velocity from the spiral data agreed well with Cartesian data. As expected, the short echo time of the spiral sequence resulted in less prominent displacement artifacts compared with the Cartesian sequence. However, both spiral and Cartesian flow rate estimates were sensitive to displacement when the flow was oblique to the encoding directions. ConclusionSpiral 3D phase contrast MRI appears favorable for the assessment of stenotic flow. The spiral sequence was more than three times faster and less sensitive to displacement artifacts when compared with a conventional Cartesian sequence.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Dyverfeldt, PetterLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US(Swepub:liu)petdy03 (author)
  • Sigfridsson, AndreasKarolinska Institutet (author)
  • Lantz, JonasLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten(Swepub:liu)jonla63 (author)
  • Carlhäll, CarljohanLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US(Swepub:liu)carca13 (author)
  • Ebbers, TinoLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US(Swepub:liu)tineb49 (author)
  • Linköpings universitetCentrum för medicinsk bildvetenskap och visualisering, CMIV (creator_code:org_t)

Related titles

  • In:Magnetic Resonance in Medicine: WILEY-BLACKWELL75:3, s. 1249-12550740-31941522-2594

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view