Repeatability and accuracy of a novel, MRI-based, semi-automated analysis method for quantifying abdominal adipose tissue and thigh muscle volumes

Middleton, Michael (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
Haufe, William (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
Hooker, Jonathan (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
visa fler...
Borga, Magnus (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Tekniska fakulteten,Advanced MR Analytics AB, Linköping, Sweden
Dahlqvist Leinhard, Olof (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Region Östergötland, Radiofysikavdelningen US,Advanced MR Analytics AB, Linköping, Sweden
Romu, Thobias (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk informatik,Tekniska fakulteten,Advanced MR Analytics AB, Linköping, Sweden
Tunón, Patrik (författare)
Advanced MR Analytics AB, Linköping, Sweden
Szeverenyi, Nick (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
Hamilton, Gavin (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
Wolfson, Tanya (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States; Computational and Applied Statistics Laboratory (CASL), University of California, San Diego, San Diego, CA, United States
Gamst, Anthony (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States; Computational and Applied Statistics Laboratory (CASL), University of California, San Diego, San Diego, CA, United States
Loomba, Rohit (författare)
Department of Medicine, University of California, San Diego, San Diego, CA, United States
Sirlin, Claude B. (författare)
Department of Radiology, University of California, San Diego, San Diego, CA, United States
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Current MRI methods to estimate body tissue compartment volumes rely on manual segmentation, which is laborious, expensive, not widely available outside specialized centers, and not standardized. To address these concerns, a novel, semi-automated image analysis method has been developed. Image acquisition takes about six minutes, and uses widely available MRI pulse sequences. We found that this method permits comprehensive body compartment analysis and provides high repeatability and accuracy. Current and future clinical and drug development studies may benefit from this methodology, as may clinical settings where monitoring change in these measures is desired.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy