SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Tesselaar Erik)
 

Sökning: WFRF:(Tesselaar Erik) > Effect of Electrode...

  • Ericsson, ElinLinköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten (författare)

Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • 2016-06-02
  • PUBLIC LIBRARY SCIENCE,2016
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-130067
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-130067URI
  • https://doi.org/10.1371/journal.pone.0155913DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Ventilator-induced or ventilator-associated lung injury (VILI/VALI) is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT) can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Tesselaar, ErikLinköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten(Swepub:liu)eridr03 (författare)
  • Sjöberg, FolkeLinköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten,Region Östergötland, Hand- och plastikkirurgiska kliniken US(Swepub:liu)folsj94 (författare)
  • Linköpings universitetAvdelningen för kliniska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:PLOS ONE: PUBLIC LIBRARY SCIENCE11:6, s. e0155913-1932-6203

Internetlänk

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ericsson, Elin
Tesselaar, Erik
Sjöberg, Folke
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
PLOS ONE
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy