A search for optimal x‐ray spectra in iodine contrast media mammography

Ullman, Gustaf (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Sandborg, Michael (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Dance, David R. (författare)
Joint Department of Physics, The Royal Marsden NHS Trust, London, UK
visa fler...
Yaffe, Martin (författare)
Department of Medical Biophysics, University of Toronto, Sunnybrook and Women's College Health Sciences Centre, Ontario, Canada
Alm Carlsson, Gudrun (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2005-06-22
2005
Engelska.
Ingår i: Physics in medicine and biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 50:13, s. 3143-3152
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this work was to search for the optimal x-ray tube voltage and anode–filter combination in digital iodine contrast media mammography. In the optimization, two entities were of interest: the average glandular dose, AGD, and the signal-to-noise ratio, SNR, for detection of diluted iodine contrast medium. The optimum is defined as the technique maximizing the figure of merit, SNR2/AGD. A Monte Carlo computer program was used which simulates the transport of photons from the x-ray tube through the compression plate, breast, breast support plate, anti-scatter grid and image detector. It computes the AGD and the SNR of an iodine detail inside the compressed breast. The breast thickness was varied between 2 and 8 cm with 10–90% glandularity. The tube voltage was varied between 20 and 55 kV for each anode material (Rh, Mo and W) in combination with either 25 µm Rh or 0.05–0.5 mm Cu added filtration. The x-ray spectra were calculated with MCNP4C (Monte Carlo N-Particle Transport Code System, version 4C). A CsI scintillator was used as the image detector. The results for Rh/0.3mmCu, Mo/0.3mmCu and W/0.3mmCu were similar. For all breast thicknesses, a maximum in the figure of merit was found at approximately 45 kV for the Rh/Cu, Mo/Cu and W/Cu combinations. The corresponding results for the Rh/Rh combination gave a figure of merit that was typically lower and more slowly varying with tube voltage. For a 4 cm breast at 45 kV, the SNR2/AGD was 3.5 times higher for the Rh/0.3mmCu combination compared with the Rh/Rh combination. The difference is even larger for thicker breasts. The SNR2/AGD increases slowly with increasing Cu-filter thickness. We conclude that tube voltages between 41 and 55 kV and added Cu-filtration will result in significant dose advantage in digital iodine contrast media mammography compared to using the Rh/Rh anode/filter combination at 25–32 kV.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy