Calculation of images from an anthropomorphic chest phantom using Monte Carlo methods

  • Artikel/kapitelEngelska2006

Förlag, utgivningsår, omfång ...

  • SPIE,2006
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-13221
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-13221URI
  • https://doi.org/10.1117/12.644119DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • Monte Carlo (MC) computer simulation of chest x-ray imaging systems has hitherto been performed using anthropomorphic phantoms with too large (3 mm) voxel sizes. The aim for this work was to develop and use a Monte Carlo computer program to compute projection x-ray images of a high-resolution anthropomorphic voxel phantom for visual clinical image quality evaluation and dose-optimization. An Alderson anthropomorphic chest phantom was imaged in a CT-scanner and reconstructed with isotropic voxels of 0.7 mm. The phantom was segmented and included in a Monte Carlo computer program using the collision density estimator to derive the energies imparted to the detector per unit area of each pixel by scattered photons. The image due to primary photons was calculated analytically including a pre-calculated detector response function. Attenuation and scatter of x-rays in the phantom, grid and image detector was considered. Imaging conditions (tube voltage, anti-scatter device) were varied and the images compared to a real computed radiography (Fuji FCR 9501) image. Four imaging systems were simulated (two tube voltages 81 kV and 141 kV using either a grid with ratio 10 or a 30 cm air gap). The effect of scattered radiation on the visibility of thoracic vertebrae against the heart and lungs is demonstrated. The simplicity in changing the imaging conditions will allow us not only to produce images of existing imaging systems, but also of hypothetical, future imaging systems. We conclude that the calculated images of the high-resolution voxel phantom are suitable for human detection experiments of low-contrast lesions.

Ämnesord och genrebeteckningar

  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Malusek, AlexandrLinköpings universitet,Medicinsk radiofysik,Hälsouniversitetet(Swepub:liu)alema80 (författare)
  • Sandborg, MichaelLinköpings universitet,Medicinsk radiofysik,Hälsouniversitetet(Swepub:liu)micsa02 (författare)
  • Dance, David R.The Royal Marsden NHS Trust, United Kingdom (författare)
  • Alm Carlsson, GudrunLinköpings universitet,Medicinsk radiofysik,Hälsouniversitetet(Swepub:liu)gudal03 (författare)
  • Linköpings universitetMedicinsk radiofysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Proceedings of SPIE: SPIE

Internetlänk

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ullman, Gustaf
Malusek, Alexand ...
Sandborg, Michae ...
Dance, David R.
Alm Carlsson, Gu ...
Artiklar i publikationen
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy