SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1617 7959 OR L773:1617 7940
 

Sökning: L773:1617 7959 OR L773:1617 7940 > (2015-2019) > A hyperelastic fibr...

A hyperelastic fibre-reinforced continuum model of healing tendons with distributed collagen fibre orientations

Bajuri, M. N. (författare)
University of Oxford, England; University of Teknol Malaysia, Malaysia
Isaksson, Hanna (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University, Sweden
Eliasson, Pernilla T. (författare)
Linköpings universitet,Avdelningen för kliniska vetenskaper,Medicinska fakulteten
visa fler...
Thompson, Mark S. (författare)
University of Oxford, England
visa färre...
 (creator_code:org_t)
2016-03-07
2016
Engelska.
Ingår i: Biomechanics and Modeling in Mechanobiology. - : SPRINGER HEIDELBERG. - 1617-7959 .- 1617-7940. ; 15:6, s. 1457-1466
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties, and in some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. Computational mechanobiology methods employed extensively to model bone healing have achieved high fidelity. This study aimed to investigate whether an established hyperelastic fibre-reinforced continuum model introduced by Gasser, Ogden and Holzapfel (GOH) can be used to capture the mechanical behaviour of the Achilles tendon under loading during discrete timepoints of the healing process and to assess the models sensitivity to its microstructural parameters. Curve fitting of the GOH model against experimental tensile testing data of rat Achilles tendons at four timepoints during the tendon repair was used and achieved excellent fits (0.9903 amp;lt; R-2 amp;lt; 0.9986). A parametric sensitivity study using a three-level central composite design, which is a fractional factorial design method, showed that the collagen-fibre-related parameters in the GOH model-kappa, k(1) and k(2)-had almost equal influence on the fitting. This study demonstrates that the GOH hyperelastic fibre-reinforced model is capable of describing the mechanical behaviour of healing tendons and that further experiments should focus on establishing the structural and material parameters of collagen fibres in the healing tissue.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Tendon healing; Constitutive model; Fibre-reinforced material; Finite element analysis; Fractional factorial design

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy