Temperature-corrected post-mortem 1.5 T MRI quantification of non-pathologic upper abdominal organs

Schwendener, Nicole (författare)
University of Bern, Switzerland
Jackowski, Christian (författare)
University of Bern, Switzerland
Schuster, Frederick (författare)
University of Bern, Switzerland
visa fler...
Persson, Anders (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
Warntjes, Marcel Jan Bertus (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Zech, Wolf-Dieter (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,University of Bern, Switzerland
visa färre...
 (creator_code:org_t)
2017-06-17
2017
Engelska.
Ingår i: International journal of legal medicine. - : SPRINGER. - 0937-9827 .- 1437-1596. ; 131:5, s. 1369-1376
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study aimed to evaluate if simultaneous temperature-corrected T1, T2, and proton density (PD) 1.5 T post-mortem MR quantification [quantitative post-mortem magnetic resonance imaging (QPMMRI)] is feasible for characterizing and discerning non-pathologic upper abdominal organs (liver, spleen, pancreas, kidney) with regard to varying body temperatures. QPMMRI was performed on 80 corpses (25 females, 55 males; mean age 56.2 years, SD 17.2) prior to autopsy. Core body temperature was measured during QPMMRI. Quantitative T1, T2, and PD values were measured in the liver, pancreas, spleen, and left kidney and temperature corrected to 37 A degrees C. Histologic examinations were conducted on each measured organ to determine non-pathologic organs. Quantitative T1, T2, and PD values of non-pathologic organs were ANOVA tested against values of other non-pathologic organ types. Based on temperature-corrected quantitative T1, T2, and PD values, ANOVA testing verified significant differences between the non-pathologic liver, spleen, pancreas, and left kidneys. Temperature-corrected 1.5 T QPMMRI based on T1, T2, and PD values may be feasible for characterization and differentiation of the non-pathologic liver, spleen, pancreas, and kidney. The results may provide a base for future specific pathology diagnosis of upper abdominal organs in post-mortem imaging.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Farmakologi och toxikologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Pharmacology and Toxicology (hsv//eng)

Nyckelord

Post-mortem magnetic resonance imaging; Post-mortem MRI quantification; Abdominal organs; Relaxation times; Proton density

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy