SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-14458"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-14458" > A protocol for iont...

A protocol for iontophoresis of acetylcholine and sodium nitroprusside that minimises nonspecific vasodilatory effects

Droog Tesselaar, Erik (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Hälsouniversitetet
Henricson, Joakim (författare)
Linköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet
Nilsson, Gert E. (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
visa fler...
Sjöberg, Folke (författare)
Östergötlands Läns Landsting,Linköpings universitet,Brännskadevård,Hälsouniversitetet,Hand- och plastikkirurgiska kliniken US
visa färre...
 (creator_code:org_t)
Elsevier BV, 2004
2004
Engelska.
Ingår i: Microvascular research. - : Elsevier BV. - 0026-2862. ; 67:2, s. 197-202
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Iontophoresis of vasoactive substances is a promising tool for studying pharmacological aspects of the (patho)physiology of the microvasculature. However, nonspecific microvascular responses are a common problem in most protocols used. We studied the effect of current density (mA/cm2), charge density (mC/cm2), drug concentration (mass %) and vehicle concentration (M) on the nonspecific vasodilatation during iontophoresis of sodium chloride, acetylcholine (ACh) and sodium nitroprusside (SNP). We found that nonspecific vasodilatation depended on current density and charge density in both anodal and cathodal iontophoresis. The responses to ACh and SNP were dependent on current density, charge density and drug concentration. We found that by limiting current density (<0.01 mA/cm2) and charge density (<7.8 mC/cm2) and with adjusted concentrations for drugs and vehicles, it is possible to prevent nonspecific effects during iontophoresis of ACh and SNP, while maximum drug effects (plateaus in the dose–response curves) are still obtained. These new findings are important for future iontophoresis studies in which vasoactive drugs are used to assess microvascular function because the presented approach has advantages compared to older techniques, which mainly have attempted to suppress or compensate for the nonspecific responses during iontophoresis by the use of local anaesthetics or the measurement of drug-minus-vehicle responses, both of which present well-known experimental shortcomings.

Nyckelord

Microcirculation
Skin
Laser Doppler
Nonspecific vasodilatation
Sodium chloride
Acetylcholine
Nitroprusside
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy