SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-14612"
 

Sökning: id:"swepub:oai:DiVA.org:liu-14612" > Myocardial perfusio...

  • Karlsson, Daniel M. G.Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan (författare)

Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique

  • Artikel/kapitelEngelska2005

Förlag, utgivningsår, omfång ...

  • Springer,2005
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-14612
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-14612URI
  • https://doi.org/10.1007/BF02351031DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Electrocardiogram (ECG)—triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and post left internal mammary artery (LIMA) graft declamping; and post aorta declamping. The perfusion signal was calculated in late systole and late diastole, with expected minimum tissue motion, and compared with arrested heart measurements. Patient conditions or artifacts caused by surgical activity made it impossible to perform and analyse data in all six phases for some patients. No significant (n=5) difference between perfusion signals pre- and post-CABG was found. Diastolic perfusion signal levels were significantly (p<0.02) lower compared with systolic levels. After aorta cross-clamping, the signal level was almost zero. A distinct perfusion signal increase after LIMA and aorta declamping, compared with pre-LIMA declamping, was found in ten cases out of 13. A significantly (p<0.04) lower perfusion signal in the arrested heart compared with in the beating heart was registered. Influence from mechanical ventilation was observed in 14 measurements out of 17. In conclusion, ECG-triggered LDPM can be used to assess myocardial perfusion during CABG. Perfusion signals were lower in the arrested heart compared with in the beating heart and in late diastole compared with late systole. No significant difference between pre- and post-CABG was found.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Fors, CarinaLinköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan(Swepub:liu)carfo18 (författare)
  • Wårdell, KarinLinköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,MINT(Swepub:liu)karwa46 (författare)
  • Casimir-Ahn, HenrikÖstergötlands Läns Landsting,Hjärtcentrum(Swepub:liu)henah22 (författare)
  • Linköpings universitetInstitutionen för medicinsk teknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical and Biological Engineering and Computing: Springer43:5, s. 582-5880140-01181741-0444

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy