Spatial frequency domain imaging using a snap-shot filter mosaic camera with multi-wavelength sensitive pixels

Strömberg, Tomas, 1966- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Saager, Rolf B., 1974- (författare)
Beckman Laser Institute and Medical Clinic, USA
Kennedy, Gordon T. (författare)
Beckman Laser Institute and Medical Clinic, USA
visa fler...
Fredriksson, Ingemar, 1980- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Salerud, Göran, 1954- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
Durkin, Anthony J. (författare)
Beckman Laser Institute and Medical Clinic, USA
Larsson, Marcus, 1974- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2018
2018
Engelska.
Ingår i: Proceedings Volume 10467, Photonics in Dermatology and Plastic Surgery 2018; 104670D (2018). - : SPIE - International Society for Optical Engineering.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Spatial frequency domain imaging (SFDI) utilizes a digital light processing (DLP) projector for illuminating turbid media with sinusoidal patterns. The tissue absorption (μa) and reduced scattering coefficient (μ,s) are calculated by analyzing the modulation transfer function for at least two spatial frequencies. We evaluated different illumination strategies with a red, green and blue light emitting diodes (LED) in the DLP, while imaging with a filter mosaic camera, XiSpec, with 16 different multi-wavelength sensitive pixels in the 470-630 nm wavelength range. Data were compared to SFDI by a multispectral camera setup (MSI) consisting of four cameras with bandpass filters centered at 475, 560, 580 and 650 nm. A pointwise system for comprehensive microcirculation analysis was used (EPOS) for comparison. A 5-min arterial occlusion and release protocol on the forearm of a Caucasian male with fair skin was analyzed by fitting the absorption spectra of the chromophores HbO2, Hb and melanin to the estimatedμa. The tissue fractions of red blood cells (fRBC), melanin (/mel) and the Hb oxygenation (S02 ) were calculated at baseline, end of occlusion, early after release and late after release. EPOS results showed a decrease in S02 during the occlusion and hyperemia during release (S02 = 40%, 5%, 80% and 51%). The fRBC showed an increase during occlusion and release phases. The best MSI resemblance to the EPOS was for green LED illumination (S02 = 53%, 9%, 82%, 65%). Several illumination and analysis strategies using the XiSpec gave un-physiological results (e.g. negative S02 ). XiSpec with green LED illumination gave the expected change in /RBC , while the dynamics in S02 were less than those for EPOS. These results may be explained by the calculation of modulation using an illumination and detector setup with a broad spectral transmission bandwidth, with considerable variation in μa of included chromophores. Approaches for either reducing the effective bandwidth of the XiSpec filters or by including their characteristic in a light transport model for SFDI modulation, are proposed.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy