SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0271 3683
 

Sökning: L773:0271 3683 > Tear Production Lev...

Tear Production Levels and Dry Eye Disease Severity in a Large Norwegian Cohort

Yazdani, Mazyar (författare)
Oslo Univ Hosp, Norway; Norwegian Dry Eye Clin, Norway
Chen, Xiangjun (författare)
Norwegian Dry Eye Clin, Norway; Arendal Hosp, Norway; Univ Oslo, Norway; Univ Coll Southeast Norway, Norway
Tashbayev, Behzod (författare)
Norwegian Dry Eye Clin, Norway; Univ Oslo, Norway
visa fler...
Utheim, Oygunn A. (författare)
Oslo Univ Hosp, Norway; Norwegian Dry Eye Clin, Norway
Raeder, Sten (författare)
Norwegian Dry Eye Clin, Norway
Lagali, Neil (författare)
Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Ögonkliniken US
Stojanovic, Aleksandar (författare)
Univ Hosp North Norway, Norway
Dartt, Darlene A. (författare)
Harvard Med Sch, MA USA
Utheim, Tor P. (författare)
Oslo Univ Hosp, Norway; Norwegian Dry Eye Clin, Norway; Arendal Hosp, Norway; Univ Oslo, Norway; Univ Coll Southeast Norway, Norway; Oslo Univ Hosp, Norway; Oslo Univ Hosp, Norway; Stavanger Univ Hosp, Norway; Univ Bergen, Norway
visa färre...
 (creator_code:org_t)
2018-09-05
2018
Engelska.
Ingår i: Current Eye Research. - : TAYLOR & FRANCIS INC. - 0271-3683 .- 1460-2202. ; 43:12, s. 1465-1470
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To determine if the Schirmer I test (without anesthesia) cut-off value is a predictor of dry eye severity in a large Norwegian cohort of dry eye disease (DED) patients, which are grouped into six levels of tear production. Methods: Patients (n = 1090) with DED of different etiologies received an extensive dry eye work-up: osmolarity (Osm), tear meniscus height (TMH), tear film break-up time (TFBUT), ocular protection index (OPI), ocular surface staining (OSS), Schirmer I test (ST), meibum expressibility (ME), and meibum quality (MQ). Classification of dry eye severity level (DESL) and diagnosis of meibomian gland dysfunction (MGD) were also included. The cohort was divided into six groups: below and above cut-off values of 5 (groups 1 and 2), 10 (groups 3 and 4), and 15 mm (groups 5 and 6) of ST. Mann-Whitney test and Chi-Square test were used for group comparison of parameters (p amp;lt;= 0.05). Results: The groups 1, 3, and 5 had values indicating more severe DED than the groups 2, 4, 6 with significant difference in DESL, Osm, TFBUT, OPI, OSS, and TMH. Regardless of the choice of cut-off values, there was no statistically significant difference in ME, MQ, and MGD between groups below and above selected cut-off value. When gender difference was considered in each group, significant difference was only observed for DESL (groups 2, 4, and 5), TFBUT (groups 2, 4, and 5), OPI (groups 2 and 6), and ME (group1). Conclusions: Schirmer I is a robust discriminator for DESL, Osm, TFBUT, OPI, OSS, and TMH, but not for ME, MQ, and MGD. Patients with lower tear production levels presented with more severe DED at all three defined cut-off values. Interestingly, the differences in the mean values of DESL were minimal although statistically significant. Thus, the clinical value of different Schirmer levels appears to be limited.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Dry eye disease; Schirmer I test; tear production levels; clinical tests; large population of patients

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy