  • Dick, H BurkhardUniversity Eye Hospital Bochum, Bochum, Germany (författare)

Evaluation of clinical outcomes following implantation of a sub-2-mm hydrophilic acrylic MICS intraocular lens

  • Artikel/kapitelEngelska2019

Förlag, utgivningsår, omfång ...

  • 2018-04-13
  • Springer Netherlands,2019
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-153462
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-153462URI
  • https://doi.org/10.1007/s10792-018-0905-3DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • PURPOSE: To evaluate clinical outcomes following sub-2-mm microincision cataract surgery (MICS) and intraocular lens (IOL) implantation.SETTING: Five EU clinical sites.DESIGN: Prospective, multicenter, open-label, single-arm, non-randomized.METHODS: Preoperative assessment involved visual acuity (VA), intraocular pressure and biometry measurements. 1.4-mm wound-assisted or 1.8-mm MICS was performed. Follow-up visits were made 1 day, 1-2 weeks, 1-2 and 4-6 months after surgery. The incision size, corrected distance VA (CDVA), uncorrected distance VA, manifest refraction spherical equivalent (MRSE), refraction predictability/stability and IOL decentration were assessed. At 12-, 18-, and 24-month, long-term centration, posterior capsular opacification (PCO) and Nd:YAG capsulotomy rates were investigated.RESULTS: A total of 103 eyes were implanted with the study IOL (INCISE, Bausch & Lomb), 96 of which were included in visual outcome analysis. A mean 6-month CDVA of - 0.02 logMAR (20/20 + 1) was observed and 75 eyes (79.8%) and 93 eyes (98.3%) achieved a visual acuity of at least 20/20 or 20/40. Mean MRSE was - 0.20 ± 0.60 D. Mean absolute predictive error was 0.44 ± 0.36 D, with 90.4% within 1.00 D of target. Mean total decentration was 0.35 ± 0.36 mm at 6 months and 0.32 ± 0.14 mm at 24 months (p > 0.05). 24-month evaluation of posterior capsular opacification score was 0.03 for the central area. A Nd:YAG rate of 3.4% was observed at 24 months.CONCLUSIONS: The new MICS IOL provided excellent visual outcomes and was safe and effective for the sub-2-mm procedure. The MICS IOL demonstrated long-term centration, stability and a low rate of PCO development.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Schultz, TimUniversity Eye Hospital Bochum, Bochum, Germany (författare)
  • Lesieur, GillesCentre Ophtalmologique Iridis, Albi, France (författare)
  • Morselli, SimonettaOspedale di Bassano del Grappa Bassano del Grappa, Bassano del Grappa, Italy (författare)
  • Toso, AntonioOspedale di Bassano del Grappa Bassano del Grappa, Bassano del Grappa, Italy (författare)
  • Alio, Jorge LVissum-Instituto Oftalmologico de Alicante, University Miguel Hernandez, Alicante, Spain (författare)
  • Buckhurst, Phillip JSchool of Health Professions, Plymouth University, Plymouth, UK (författare)
  • Johansson, Björn,1958-Linköpings universitet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Ögonkliniken US,St. Erik Eye Hospital, Stockholm, Sweden(Swepub:liu)bjojo58 (författare)
  • University Eye Hospital Bochum, Bochum, GermanyCentre Ophtalmologique Iridis, Albi, France (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:International ophtalmology: Springer Netherlands39:5, s. 1043-10540165-57011573-2630