  • Nowadays, many different kinds of bone-conduction devices (BCDs) are available for hearing rehabilitation. Most studies of these devices fail to compare the different types of BCDs under the same conditions. Moreover, most results are between two BCDs in the same subject, or two BCDs in different subjects failing to provide an overview of the results between several of the BCDs. Another issue is that some BCDs require surgical procedures that prevent comparison of the BCDs in the same persons. In this study, four types of skin-drive BCDs, three direct-drive BCDs, and one oral device were evaluated in a finite-element model of the human head that was able to simulate all BCDs under the same conditions. The evaluation was conducted using both a dynamic force as input and an electric voltage to a model of a BCD vibrator unit. The results showed that the direct-drive BCDs and the oral device gave vibration responses within 10 dB at the cochlea. The skin-drive BCDs had similar or even better cochlear vibration responses than the direct-drive BCDs at low frequencies, but the direct-drive BCDs gave up to 30 dB higher cochlear vibration responses at high frequencies. The study also investigated the mechanical point impedance at the interface between the BCD and the head, providing information that explains some of the differences seen in the results. For example, when the skin-drive BCD attachment area becomes too small, the transducer cannot provide an output force similar to the devices with larger attachment surfaces.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

bone conduction; bone-conducted sound; finite-element model; bone-conduction devices; human head

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Chang, You
Stenfelt, Stefan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oto rhino laryng ...
Artiklar i publikationen
TRENDS IN HEARIN ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy