SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hagiwara Akifumi)
 

Sökning: WFRF:(Hagiwara Akifumi) > Myelin Measurement :

Myelin Measurement : Comparison Between Simultaneous Tissue Relaxometry, Magnetization Transfer Saturation Index, and T1w/T2w Ratio Methods

Hagiwara, Akifumi (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan. a-hagiwara@juntendo.ac.jp; Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
Hori, Masaaki (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
Kamagata, Koji (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
visa fler...
Warntjes, Marcel, 1973- (författare)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US,SyntheticMR AB, Linköping, Sweden
Matsuyoshi, Daisuke (författare)
Araya Inc., Tokyo, Japan; Research Institute for Science and Engineering, Waseda University, Waseda, Japan; Research Center for Advanced Science and Technology, The University of Tokyo, Tokyo, Japan
Nakazawa, Misaki (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
Ueda, Ryo (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan; Office of Radiation Technology, Keio University Hospital, Tokyo, Japan
Andica, Christina (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
Koshino, Saori (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan; Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
Maekawa, Tomoko (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan; Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
Irie, Ryusuke (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan; Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
Takamura, Tomohiro (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
Kumamaru, Kanako Kunishima (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
Abe, Osamu (författare)
Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
Aoki, Shigeki (författare)
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
visa färre...
Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan a-hagiwara@juntendo.ac.jp; Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan (creator_code:org_t)
2018-07-12
2018
Engelska.
Ingår i: Scientific Reports. - : Nature Publishing Group. - 2045-2322. ; 8:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Magnetization transfer (MT) imaging has been widely used for estimating myelin content in the brain. Recently, two other approaches, namely simultaneous tissue relaxometry of R1 and R2 relaxation rates and proton density (SyMRI) and the ratio of T1-weighted to T2-weighted images (T1w/T2w ratio), were also proposed as methods for measuring myelin. SyMRI and MT imaging have been reported to correlate well with actual myelin by histology. However, for T1w/T2w ratio, such evidence is limited. In 20 healthy adults, we examined the correlation between these three methods, using MT saturation index (MTsat) for MT imaging. After calibration, white matter (WM) to gray matter (GM) contrast was the highest for SyMRI among these three metrics. Even though SyMRI and MTsat showed strong correlation in the WM (r?=?0.72), only weak correlation was found between T1w/T2w and SyMRI (r?=?0.45) or MTsat (r?=?0.38) (correlation coefficients significantly different from each other, with p values?amp;lt;?0.001). In subcortical and cortical GM, these measurements showed moderate to strong correlations to each other (r?=?0.54 to 0.78). In conclusion, the high correlation between SyMRI and MTsat indicates that both methods are similarly suited to measure myelin in the WM, whereas T1w/T2w ratio may be less optimal.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy