Sound analysis of the magnetically levitated left ventricular assist device HeartMate 3™

Sundbom, Per, 1981- (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken US,Department of Medicine and Geriatrics, Höglandet Hospital, Eksjö
Roth, Michael, 1984- (author)
Linköpings universitet,Reglerteknik,Tekniska fakulteten
Granfeldt, Hans, 1960- (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Thorax-kärlkliniken i Östergötland
show more...
Karlsson, Daniel M., 1974- (author)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska fakulteten
Ahn, Henrik, 1949- (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Thorax-kärlkliniken i Östergötland
Gustafsson, Fredrik, 1964- (author)
Linköpings universitet,Reglerteknik,Tekniska fakulteten
Dellgren, Göran (author)
Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg; Transplant Institute, Sahlgrenska University Hospital, Gothenburg
Hübbert, Laila, 1964- (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken i Norrköping,Transplant Institute, Sahlgrenska University Hospital, Gothenburg
show less...
 (creator_code:org_t)
2019-06-28
2019
English.
In: International Journal of Artificial Organs. - : Sagamore Publishing. - 0391-3988 .- 1724-6040. ; 42:12, s. 717-724
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • INTRODUCTION: The HeartMate 3™ has shown lower rates of adverse events compared to previous devices due to the design and absence of mechanical bearings. For previous devices, sound analysis emerged as a way to assess pump function. The aims of this study were to determine if sound analysis can be applied to the HeartMate 3 in vivo and in vitro and to evaluate an electronic stethoscope.METHOD: Sound recordings were performed with microphones and clinical accessible electronic stethoscope. The recordings were studied in both the time and the frequency domains. Recordings from four patients were performed to determine if in vivo and in vitro recordings are comparable.RESULTS: The results show that it is possible to detect sound from HeartMate 3 and the sound spectrum is clear. Pump frequency and frequency of the pulsatile mode are easily determined. Frequency spectra from in vitro and in vivo recordings have the same pattern, and the major proportion (96.7%) of signal power is located at the pump speed frequency ±40 Hz. The recordings from the patients show low inter-individual differences except from location of peaks originating from pump speed and harmonics. Electronic stethoscopes could be used for sound recordings, but the dedicated equipment showed a clearer sound spectrum.DISCUSSION: The results show that acoustic analysis can also be performed with the HeartMate 3 and that in vivo and in vitro sound spectrum is similar. The frequency spectra are different from previous devices, and methods for assessing pump function or thrombosis need further evaluation.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Keyword

HeartMate 3
Spectral analysis
left ventricular assist device
sound

Publication and Content Type

ref (subject category)
art (subject category)