Low-cost chemical gas sensors for selective formaldehyde quantification at ppb-level in field tests

Bastuck, Manuel (författare)
Saarland University, Lab for Measurement Technology, Germany
Puglisi, Donatella, 1980- (författare)
Linköpings universitet,Sensor- och aktuatorsystem,Tekniska fakulteten
Möller, Peter, 1978- (författare)
Linköpings universitet,Sensor- och aktuatorsystem,Tekniska fakulteten
visa fler...
Reimringer, Wolfhard (författare)
3S GmbH, Saarbrücken, Germany
Schuetze, Andreas (författare)
Saarland University, Germany,Lab for Measurement Technology
Lloyd Spetz, Anita, 1951- (författare)
Linköpings universitet,Sensor- och aktuatorsystem,Tekniska fakulteten,Applied Sensor Science
Andersson, Mike, 1977- (författare)
Linköpings universitet,Sensor- och aktuatorsystem,Tekniska fakulteten,Applied Sensor Science
visa färre...
 (creator_code:org_t)
2017
2017
Engelska.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Data from a silicon carbide based field-effect transistor were recorded over a period of nine days in a ventilated school room. For enhanced sensitivity and selectivity especially to formaldehyde, porous iridium on pulsed laser deposited tungsten trioxide was used as sensitive layer, in combination with temperature cycled operation and subsequent multivariate data processing techniques. The sensor signal was compared to reference measurements for formaldehyde concentration, CO2 concentration, temperature, and relative humidity. The results show a distinct pattern for the reference formaldehyde concentration, arising from the day/night cycle. Taking this into account, the projections of both principal component analysis and partial least squares regression lead to almost the same result concerning correlation to the reference. The sensor shows cross-sensitivity to an unidentified component of human activity, presumably breath, and, possibly, to other compounds appearing together with formaldehyde in indoor air. Nevertheless, the sensor is able to detect and partially quantify formaldehyde below 40 ppb with a correlation to the reference of 0.48 and negligible interference from ambient temperature or relative humidity.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Annan kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Other Chemical Engineering (hsv//eng)

Nyckelord

SiC-FET
multivariate data processing
indoor air quality
VOC
sick building syndrome