SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kallner Anders)
 

Sökning: WFRF:(Kallner Anders) > (2020) > Repeatability impre...

Repeatability imprecision from analysis of duplicates of patient samples and control materials

Kallner, Anders (författare)
Karolinska Institutet,Karolinska Univ Hosp, Sweden
Theodorsson, Elvar (författare)
Linköpings universitet,Avdelningen för klinisk kemi,Medicinska fakulteten,Region Östergötland, Klinisk kemi
 (creator_code:org_t)
2020-01-03
2020
Engelska.
Ingår i: Scandinavian Journal of Clinical and Laboratory Investigation. - : TAYLOR & FRANCIS LTD. - 0036-5513 .- 1502-7686. ; 80:3, s. 210-214
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Measurement imprecision is usually calculated from measurement results of the same stabilized control material(s) obtained over time, and is therefore, principally, only valid at the concentration(s) of the selected control material(s). The resulting uncertainty has been obtained under reproducibility conditions and corresponds to the conventional analytical goals. Furthermore, the commutability of the control materials used determines whether the imprecision calculated from the control materials reflects the imprecision of measuring patient samples. Imprecision estimated by measurements of patient samples uses fully commutable samples, freely available in the laboratories. It is commonly performed by calculating the results of routine patient samples measured twice each. Since the duplicates are usually analysed throughout the entire concentration interval of the patient samples processed in the laboratory, the result will be a weighted average of the repeatability imprecision measured in the chosen measurement intervals or throughout the entire interval of concentrations encountered in patient care. In contrast, the uncertainty derived from many measurements of control materials over periods of weeks is usually made under reproducibility conditions. Consequently, the repeatability and reproducibility imprecision play different roles in the inference of results in clinical medicine. The purpose of the present review is to detail the properties of the imprecision calculated by duplicates of natural samples, to explain how it differs from imprecision calculated from single concentrations of control materials, and to elucidate what precautions need to be taken in case of bias, e.g. due to carry-over effects.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)

Nyckelord

Dahlberg formula; analysis of variance components; repeatability; reproducibility; total variance; bias

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kallner, Anders
Theodorsson, Elv ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
Artiklar i publikationen
Scandinavian Jou ...
Av lärosätet
Linköpings universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy