Sökning: (WFRF:(Romu Thobias)) >
Reproducibility and...
-
Borga, MagnusLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden
(författare)
Reproducibility and repeatability of MRI-based body composition analysis
- Artikel/kapitelEngelska2020
Förlag, utgivningsår, omfång ...
-
2020-06-10
-
WILEY,2020
-
electronicrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:liu-167407
-
https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-167407URI
-
https://doi.org/10.1002/mrm.28360DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Funding Agencies|Swedish Research CouncilSwedish Research Council [VR 2019-04751]
-
Purpose There is an absence of reproducibility studies on MRI-based body composition analysis in current literature. Therefore, the aim of this study was to investigate the between-scanner reproducibility and the repeatability of a method for MRI-based body composition analysis. Methods Eighteen healthy volunteers of varying body mass index and adiposity were each scanned twice on five different 1.5T and 3T scanners from three different vendors. Two-point Dixon neck-to knee images and two additional liver scans were acquired with similar protocols. Visceral adipose tissue (VAT) volume, abdominal subcutaneous adipose tissue (ASAT) volume, thigh muscle volume, and muscle fat infiltration (MFI) in the thigh muscle were measured. Liver proton density fat fraction (PDFF) was assessed using two different methods, the scanner vendors 6-point method and an in-house 2-point method. Within-scanner test-retest repeatability and between-scanner reproducibility were calculated using analysis of variance. Results Repeatability coefficients were 13 centiliters (cl) (VAT), 24 cl (ASAT), 17 cl (total thigh muscle volume), 0.53% (MFI), and 1.27-1.37% for liver PDFF. Reproducibility coefficients were 24 cl (VAT), 42 cl (ASAT), 31 cl (total thigh muscle volume), 1.44% (MFI), and 2.37-2.40% for liver PDFF. Conclusion For all measures except MFI, the within-scanner repeatability explained much of the overall reproducibility. The two methods for measuring liver fat had similar reproducibility. This study showed that the investigated method eliminates effects due to scanner differences. The results can be used for power calculations in clinical studies or to better understand the scanner-induced variability in clinical applications.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Ahlgren, AndreAMRA Med AB, Linkoping, Sweden
(författare)
-
Romu, ThobiasAMRA Med AB, Linkoping, Sweden
(författare)
-
Widholm, PerLinköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping,AMRA Med AB, Linkoping, Sweden(Swepub:liu)perwi01
(författare)
-
Dahlqvist Leinhard, Olof,1978-Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden(Swepub:liu)oloda24
(författare)
-
West, JanneLinköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Med AB, Linkoping, Sweden(Swepub:liu)janwe85
(författare)
-
Linköpings universitetAvdelningen för medicinsk teknik
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Magnetic Resonance in Medicine: WILEY84:6, s. 3146-31560740-31941522-2594
Internetlänk
Hitta via bibliotek
Till lärosätets databas