SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Carlsson Tedgren Åsa)
 

Sökning: WFRF:(Carlsson Tedgren Åsa) > Experimental assess...

Experimental assessment of a phosphor model for estimating the relative extrinsic efficiency in radioluminescent detectors

Lindstrom, Jan (författare)
Karolinska Univ Hosp, Sweden
Alm Carlsson, Gudrun (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik
Wahlin, Erik (författare)
Karolinska Univ Hosp, Sweden
visa fler...
Carlsson Tedgren, Åsa (författare)
Karolinska Institutet,Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Medicinsk strålningsfysik,Karolinska Univ Hosp, Sweden
Poludniowski, Gavin (författare)
Karolinska Institutet,Karolinska Univ Hosp, Sweden
visa färre...
 (creator_code:org_t)
Elsevier, 2020
2020
Engelska.
Ingår i: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 76, s. 117-124
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Optimising phosphor screens in dose detectors or imaging sensor designs is a cumbersome and time- consuming work normally involving specialised measuring equipment and advanced modelling. It is known that crucial optical parameters of the same phosphor may vary within a wide range of values. The aim of this work was to experimentally assess a simple previously published model where the case specific optical parameters (scattering and absorption) are instead represented by a fixed, single parameter, the light extinction factor, xi. The term extrinsic efficiency, N, of a phosphor is also introduced, differing from the common denotation "absolute efficiency", after noting that unknown factors (such as temperature dependence) can have an influence during efficiency estimations and hence difficult to claim absoluteness. N is expressed as the ratio of light energy emitted per unit area at the phosphor surface to incident x-ray energy fluence. By focusing on ratios and relative changes in this study, readily available instruments in a Medical Physics Department (i.e. a photometer) could be used. The varying relative extrinsic efficiency for an extended range of particle sizes (7.5 and 25 mu m) and layer thicknesses (220 to 830 mu m) were calculated in the model from the input parameters: the mean particle size of the phosphor, the layer thickness, the light extinction factor and the calculated energy imparted to the layer. In-house manufactured screens (Gd2O2S:Tb) were used for better control of design parameters. The model provided good qualitative agreement to experiment with quantitative deviations in relative extrinsic efficiency within approximately 2%.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Energy transport; Extrinsic efficiency; Fluorescence; Optimisation; Phosphor model; Radioluminescence

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy