SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1432 2307
 

Sökning: L773:1432 2307 > The histopathologic...

The histopathological diagnosis of atypical meningioma: glass slide versus whole slide imaging for grading assessment

Ammendola, Serena (författare)
Univ Verona, Italy
Bariani, Elena (författare)
Univ Verona, Italy
Eccher, Albino (författare)
Univ & Hosp Trust Verona, Italy
visa fler...
Capitanio, Arrigo (författare)
Linköpings universitet,Avdelningen för neurobiologi,Medicinska fakulteten,Region Östergötland, Klinisk patologi
Ghimenton, Claudio (författare)
Univ & Hosp Trust Verona, Italy
Pantanowitz, Liron (författare)
Univ Michigan, MI 48109 USA
Parwani, Anil (författare)
Ohio State Univ, OH 43210 USA
Girolami, Ilaria (författare)
Cent Hosp Bolzano, Italy
Scarpa, Aldo (författare)
Univ Verona, Italy; Univ & Hosp Trust Verona, Italy
Barresi, Valeria (författare)
Univ Verona, Italy; Polyclin GB Rossi, Italy
visa färre...
 (creator_code:org_t)
2020-12-10
2021
Engelska.
Ingår i: Virchows Archiv. - : SPRINGER. - 0945-6317 .- 1432-2307. ; 478, s. 747-756
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Limited studies on whole slide imaging (WSI) in surgical neuropathology reported a perceived limitation in the recognition of mitoses. This study analyzed and compared the inter- and intra-observer concordance for atypical meningioma, using glass slides and WSI. Two neuropathologists and two residents assessed the histopathological features of 35 meningiomas-originally diagnosed as atypical-in a representative glass slide and corresponding WSI. For each histological parameter and final diagnosis, we calculated the inter- and intra-observer concordance in the two viewing modes and the predictive accuracy on recurrence. The concordance rates for atypical meningioma on glass slides and on WSI were 54% and 60% among four observers and 63% and 74% between two neuropathologists. The inter-observer agreement was higher using WSI than with glass slides for all parameters, with the exception of high mitotic index. For all histological features, we found median intra-observer concordance of >= 79% and similar predictive accuracy for recurrence between the two viewing modes. The higher concordance for atypical meningioma using WSI than with glass slides and the similar predictive accuracy for recurrence in the two modalities suggest that atypical meningioma may be safely diagnosed using WSI.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Nyckelord

Atypical meningioma; Whole slide imaging; Digital; Recurrence; Reproducibility

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy