Impact of the I-value of diamond on the energy deposition in different beam qualities

Kaveckyte, Vaiva, 1991- (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten
Carlsson Tedgren, Åsa, 1968- (författare)
Karolinska Institutet,Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
Varea, José María Fernández (författare)
Facultat de Física (FQA and ICC), Universitat de Barcelona, Barcelona, Catalonia, Spain
 (creator_code:org_t)
2021-06-07
2021
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 66:12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Diamond detectors are increasingly employed in dosimetry. Their response has been investigated by means of Monte Carlo (MC) methods, but there is no consensus on what mass density ρ, mean excitation energy I and number of conduction electrons per atom nce to use in the simulations. The ambiguity occurs due to its seeming similarity with graphite (both are carbon allotropes). Contrary to diamond, graphite has been well-characterized. Except for the difference in ρ between crystalline graphite (2.265 g cm-3) and diamond (3.515 g cm-3), their dielectric properties are assumed to be identical. This is incorrect, and the two materials should be distinguished: (ρ = 2.265 g cm-3, I = 81.0 eV, nce = 1) for graphite and (ρ = 3.515 g cm-3, I = 88.5 eV, nce = 0) for diamond. Simulations done with the MC code PENELOPE show that the energy imparted in diamond decreases by up to 1% with respect to 'pseudo-diamond' (ρ = 3.515 g cm-3, I = 81.0 eV, nce = 0) depending on the beam quality and cavity thickness. The energy imparted changed the most in cavities that are small compared with the range of electrons. The difference in the density-effect term relative to graphite was the smallest for diamond owing to an interplay effect that ρ, I and nce have on this term, in contrast to pseudo-diamond media when either ρ or I alone were adjusted. The study also presents a parameterized density-effect correction function for diamond that may be used by MC codes like EGSnrc. The ESTAR program assumes that nce = 2 for all carbon-based materials, hence it delivers an erroneous density-effect correction term for graphite and diamond. Despite the small changes of the energy imparted in diamond simulated with two different I values and expected close-to-negligible deviation from the published small-field output correction data, it is important to pay attention to material properties and model the medium faithfully.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Diamond
graphite
mass electronic stopping power
density-effect correction
Monte Carlo simulation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy