The effect on precision and T1 bias comparing two flip angles when estimating muscle fat infiltration using fat-referenced chemical shift-encoded imaging

Karlsson, Anette, 1986- (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Peolsson, Anneli, 1967- (författare)
Linköpings universitet,Avdelningen för prevention, rehabilitering och nära vård,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Romu, Thobias (författare)
AMRA Medical AB, Linköping, Sweden
visa fler...
Dahlqvist Leinhard, Olof, 1978- (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,AMRA Medical AB, Linköping, Sweden
Spetz, Anna-Clara, 1973- (författare)
Linköpings universitet,Medicinska fakulteten,Avdelningen för barns och kvinnors hälsa,Region Östergötland, Kvinnokliniken US
Thorell, Sofia (författare)
Linköpings universitet,Institutionen för biomedicinska och kliniska vetenskaper,Medicinska fakulteten
West, Janne, 1982- (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Tekniska fakulteten,Avdelningen för medicinsk teknik,AMRA Medical AB, Linköping, Sweden
Borga, Magnus, 1965- (författare)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för medicinsk teknik,Tekniska fakulteten,AMRA Medical AB, Linköping, Sweden
visa färre...
 (creator_code:org_t)
2021-07-07
2021
Engelska.
Ingår i: NMR in Biomedicine. - : John Wiley & Sons. - 0952-3480 .- 1099-1492. ; 34:11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Investigation of the effect on accuracy and precision of different parameter settings is important for quantitative Magnetic Resonance Imaging. The purpose of this study was to investigate T1-bias and precision for muscle fat infiltration (MFI) using fat-referenced chemical shift magnetic resonance imaging at 5° and 10° flip angle. This [MB1] experimental study was done on forty postmenopausal women using 3T MRI test and retest images using 4-point 3D spoiled gradient multi-echo acquisition including real and imaginary images for reconstruction acquired at Flip angles 5° and 10°. Post-processing included T2* correction and fat-referenced calibration of the fat signal. The mean MFI was calculated in six different automatically segmented muscle regions using both the fat-referenced fat signal and the fat fraction calculated from the fat and water image pair for each acquisition. The variance of the difference between mean MFI from test and retest was used as measure of precision. The SNR characteristics were analyzed by measuring difference of the full width half maximum of the fat signal distribution using Student’s t-test.There was no difference in the mean fat-referenced MFI at different flip angles with the fat-referenced technique, which was the case using the fat fraction. No significant difference in the precision was found in any of the muscles analyzed. However, the full width half maximum of the fat signal distribution was significantly lower at 10° flip angle compared to 5°. Fat-referenced MFI is insensitive to T1 bias in chemical shift magnetic resonance imaging enabling usage of a higher and more SNR effective flip angle. The lower full-width-at half-maximum in fat-referenced MFI at 10° indicates that high flip angle acquisition is advantageous although no significant differences in precision was observed comparing 5° and 10°.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

chemical shift-encoded MRI; flip angle; magnetic resonance imaging; muscle fat infiltration; quantification

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy