Usability and inter-rater reliability of the NeuroMotion app : A tool in General Movements Assessments

Svensson, Katarina (författare)
Linköpings universitet,Avdelningen för barns och kvinnors hälsa,Medicinska fakulteten,Region Östergötland, H.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus
Örtqvist, Maria (författare)
Karolinska Institutet,Karolinska Inst, Sweden
Bos, Arend F. (författare)
Univ Groningen, Netherlands
visa fler...
Eliasson, Ann-Christin (författare)
Karolinska Institutet,Karolinska Inst, Sweden
Sundelin, Heléne (författare)
Karolinska Institutet,Linköpings universitet,Avdelningen för barns och kvinnors hälsa,Medicinska fakulteten,Region Östergötland, H.K.H. Kronprinsessan Victorias barn- och ungdomssjukhus,Karolinska Inst, Sweden
visa färre...
 (creator_code:org_t)
Elsevier Science Ltd, 2021
2021
Engelska.
Ingår i: European journal of paediatric neurology. - : Elsevier Science Ltd. - 1090-3798 .- 1532-2130. ; 33, s. 29-35
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Early intervention after perinatal brain insults requires early detection of infants with cerebral palsy (CP). General Movements Assessments (GMA) in the fidgety movement period has a high predictive value for CP. Aim: To investigate the NeuroMotionTM apps usability regarding film quality and user experience and to assess the inter-rater reliability of GMA in a neonatal risk group. Methods: GMA, inter-rater reliability and film quality was assessed in a cohort consisting of 37 infants enrolled in a multicentre study of GMA as part of the Swedish neonatal follow-up program for high-risk infants. Some of these infants were filmed twice. For evaluation of user experience 95 parents of 52 infants were addressed with a web-based questionnaire. A GMA expert assessed film quality and performed GMA and three on-site assessors, individually performed GMA. Inter-rater reliability was computed using Krippendorffs alpha (k-alpha). Results: In all, 45 films showed good or excellent quality. The response rate of the questionnaire survey was 40% and revealed predominantly positive perceptions of the NeuroMotionTM app. GMA in 36 infants resulted in substantial agreement (k-alpha = 0.72, 95%CI = 0.3-1.0) between the three on-site assessors consensus and the GMA expert. Inter-rater reliability for GMA between the on-site assessors was moderate (k-alpha = 0.48, 0.18-0.74). Conclusion: The NeuroMotionTM app produces good technical quality films and the app user experience was overall positive. High agreement was observed between the on-site assessors and the GMA expert. The study design is feasible for more extensive GMA studies in cohorts of infants at risk of CP. (c) 2021 The Authors. Published by Elsevier Ltd on behalf of European Paediatric Neurology Society. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Nyckelord

Cerebral palsy; General movement assessment; Infant; Inter-rater reliability; Smartphone application

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy