SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Fredriksson Ingemar 1980 )
 

Search: WFRF:(Fredriksson Ingemar 1980 ) > Model-based quantit...

Model-based quantitative laser Doppler flowmetry in skin

Fredriksson, Ingemar, 1980- (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Larsson, Marcus (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Strömberg, Tomas (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
 (creator_code:org_t)
Society of Photo-optical Instrumentation Engineers, 2010
2010
English.
In: Journal of Biomedical Optics. - : Society of Photo-optical Instrumentation Engineers. - 1083-3668 .- 1560-2281. ; 15:5
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Laser Doppler Flowmetry (LDF) can be used for assessing the microcirculatory perfusion. However, conventional LDF (cLDF) gives only a relative perfusion estimate in an unknown measurement volume. To overcome these limitations a model-based analysis method for quantitative LDF (qLDF) is proposed. The method uses an inverse Monte Carlo technique with an adaptive three layer skin model. By analyzing the optimal model where measured and simulated LDF spectra using two different source-detector separations match, the absolute microcirculatory perfusion for a specified velocity region in a predefined volume is determined. The robustness of the qLDF method and how much it is affected by physiologically relevant variations in optical properties were evaluated using additional Monte Carlo simulations. When comparing qLDF to cLDF, a much smaller deviation from the true perfusion was attained. For physiologically relevant variations in the optical properties of static tissue and blood absorption, qLDF displayed errors <12%. Variations in the scattering properties of blood displayed larger errors (<58%). Evaluations on inhomogeneous models containing small blood vessels, hair and sweat glands displayed errors <5%. For extremely inhomogeneous models containing larger blood vessels, the error increased substantially, but this was detected by analyzing the qLDF model residual. The qLDF algorithm was applied to an in vivo local heat provocation. The perfusion increase was higher with qLDF than cLDF, due to non-linear effects in the latter. The qLDF showed that the perfusion increase was due to an increased amount of blood cells with a velocity > 1 mm/s.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

laser Doppler flowmetry
microcirculation
tissue modeling
inverse Monte Carlo
quantitative measures
flow speed differentiation
Medical engineering
Medicinsk teknik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Fredriksson, Ing ...
Larsson, Marcus
Strömberg, Tomas
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Journal of Biome ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view