SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Fredriksson Ingemar 1980 )
 

Sökning: WFRF:(Fredriksson Ingemar 1980 ) > Model-based quantit...

  • Fredriksson, Ingemar,1980-Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan (författare)

Model-based quantitative laser Doppler flowmetry in skin

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • Society of Photo-optical Instrumentation Engineers,2010
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-20445
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-20445URI
  • https://doi.org/10.1117/1.3484746DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Laser Doppler Flowmetry (LDF) can be used for assessing the microcirculatory perfusion. However, conventional LDF (cLDF) gives only a relative perfusion estimate in an unknown measurement volume. To overcome these limitations a model-based analysis method for quantitative LDF (qLDF) is proposed. The method uses an inverse Monte Carlo technique with an adaptive three layer skin model. By analyzing the optimal model where measured and simulated LDF spectra using two different source-detector separations match, the absolute microcirculatory perfusion for a specified velocity region in a predefined volume is determined. The robustness of the qLDF method and how much it is affected by physiologically relevant variations in optical properties were evaluated using additional Monte Carlo simulations. When comparing qLDF to cLDF, a much smaller deviation from the true perfusion was attained. For physiologically relevant variations in the optical properties of static tissue and blood absorption, qLDF displayed errors <12%. Variations in the scattering properties of blood displayed larger errors (<58%). Evaluations on inhomogeneous models containing small blood vessels, hair and sweat glands displayed errors <5%. For extremely inhomogeneous models containing larger blood vessels, the error increased substantially, but this was detected by analyzing the qLDF model residual. The qLDF algorithm was applied to an in vivo local heat provocation. The perfusion increase was higher with qLDF than cLDF, due to non-linear effects in the latter. The qLDF showed that the perfusion increase was due to an increased amount of blood cells with a velocity > 1 mm/s.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Larsson, MarcusLinköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan(Swepub:liu)marla29 (författare)
  • Strömberg, TomasLinköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan(Swepub:liu)tomst50 (författare)
  • Linköpings universitetBiomedicinsk instrumentteknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Biomedical Optics: Society of Photo-optical Instrumentation Engineers15:51083-36681560-2281

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Fredriksson, Ing ...
Larsson, Marcus
Strömberg, Tomas
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Journal of Biome ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy