SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindberg Lars Göran)
 

Sökning: WFRF:(Lindberg Lars Göran) > (2000-2004) > On-line monitoring ...

  • Fridolin, Ivo,1971-Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan (författare)

On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation

  • Artikel/kapitelEngelska2003

Förlag, utgivningsår, omfång ...

  • 2003
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-24476
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-24476URI
  • https://doi.org/10.1007/BF02348430DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180–380 nm. Concentrations of several removed substances, such as urea, creatinine, uric acid, phosphate and β 2-microglobulin, were determined in the blood and in the spent dialysate samples using standard laboratory techniques. Millimolar extinction coefficients, for urea, creatinine, monosodium phosphate and uric acid were determined during laboratory bench experiments. The correlation between UV absorbance and substances both in the dialysate and in the blood was calculated at all wavelengths. A time-dependent UV absorbance was determined on the collected dialysate samples from a single dialysis session over a wavelength range of 200–330 nm. The highest contribution from observed compounds relative to the mean value of the absorbance was found around 300 nm and was approximately 70%. The main contribution to the total absorbance from uric acid was confirmed at this wavelength. The highest correlation for uric acid, creatinine and urea was obtained at wavelengths from 280 nm to 320 nm, both in the spent dialysate and in the blood. The wavelength region with the highest correlation for phosphate and β 2-microglobulin, with a suitable UV-absorbance dynamic range, was from 300 to 330 nm. In the wavelength range of 220–270 nm the highest absorbance sensitivity for the observed substances was obtained. A suitable wavelength range for instrumental design seems tobe around 290–330 nm. The relatively high correlation between UV absorbance and the substances in the spent dialysate and in the blood indicates that the UV-absorbance technique can estimate the removal of several retained solutes known to accumulate in dialysis patients.

Ämnesord och genrebeteckningar

  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Lindberg, Lars-Göran,1951-Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan(Swepub:liu)larli69 (författare)
  • Linköpings universitetInstitutionen för medicinsk teknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical and Biological Engineering and Computing41:3, s. 263-2700140-01181741-0444

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Fridolin, Ivo, 1 ...
Lindberg, Lars-G ...
Artiklar i publikationen
Medical and Biol ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy