Surface plasmon resonance and free oscillation rheometry in combination : a useful approach for studies on haemostasis and interactions between whole blood and artificial surfaces

Hansson, Kenny, 1972- (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
Tengvall, Pentti (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Lundström, Ingemar (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
visa fler...
Rånby, Mats (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
Lindahl, Tomas, 1954- (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Biosensors & bioelectronics. - 0956-5663 .- 1873-4235. ; 17:9, s. 747-759
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In haemostatic and biomaterial research biological processes at surfaces and in the bulk phase of the surface-contacting medium are important. The present work demonstrates the usefulness of the combination of surface plasmon resonance (SPR), sensitive to changes in refractive index at surfaces, and free oscillation rheometry (FOR), sensitive to rheological properties of the bulk, for simultaneous real-time measurements on coagulation and fibrinolysis of blood plasma and coagulation of whole blood. SFLLRN stimulated coagulation of native whole blood presented a higher SPR signal with different appearance than plasma coagulation, while the FOR signals corresponding to plasma and whole blood coagulation were similar. This indicated that the SPR technique was more sensitive to cell-surface interactions than to fibrin formation in whole blood during coagulation, while the FOR technique were equally sensitive to coagulation in whole blood and plasma. Spontaneous coagulation of native whole blood in contact with methyl- and hydroxyl-terminated self-assembled monolayers (SAM) on gold and gold surfaces regenerated after coagulation were also studied. The regenerated gold surfaces displayed the shortest coagulation times, although the contact-activation of blood coagulation for these surfaces was low. The methylated and hydroxylated surfaces were comparable in terms of coagulation activation, while the hydroxylated surfaces presented FOR signals that indicated detaching of the coagulum from the surface. The combination of SPR and FOR is well suited for studies of cell– and protein–surface interactions and simultaneous bulk processes. Possible applications are investigations of blood cell defects in patients and monitoring of native whole blood interactions with artificial surfaces.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy