SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-27732"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-27732" > Reproducibility of ...

  • Larsson, Barbro,1952-Linköpings universitet,Rehabiliteringsmedicin,Hälsouniversitetet (författare)

Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions

  • Artikel/kapitelEngelska1999

Förlag, utgivningsår, omfång ...

  • 1999
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-27732
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-27732URI
  • https://doi.org/10.1016/S1050-6411(99)00006-1DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The interpretation of the electromyogram (EMG) of dynamic contractions might be difficult because the movement per se introduces additional factors that could affect its characteristics. There is a lack of studies concerning the reproducibility of surface EMG registrations during dynamic contractions. The aim was to investigate the during-the-day reproducibility (using intra-class correlation; ICC) of the peak torque (PT) and the EMG variables (without removing the electrodes) of dynamic contractions. Ten healthy subjects performed three sets of 10 dynamic maximum right-knee extensions with a one-hour interval in between, using an isokinetic dynamometer and the PT was determined. EMG signals were recorded from the right vastus lateralis, rectus femoris and vastus medialis muscles using surface electrodes and the mean frequency of the power spectrum (MNF [Hz]) and the signal amplitude (RMS [μV]), were computed. The ability to relax in-between the maximum extensions was calculated as a ratio of the RMS during the passive flexion phase and the RMS during the active extension phase of each contraction cycle: the signal amplitude ratio (SAR).Both PT (ICC=0.99) and RMS (ICC=0.83–0.98) had good reproducibility. The reproducibility of MNF was good for all muscles when the mean of contraction nos.: 1–10 was used. Vastus lateralis had the highest ICC among the three muscles. The reproducibility of SAR was generally poor (ICC<0.60). The present study showed good reproducibility for common EMG variables (MNF and RMS) obtained during maximum isokinetic contractions.

Ämnesord och genrebeteckningar

  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Månsson, BjarneLinköpings universitet,Rehabiliteringsmedicin,Hälsouniversitetet(Swepub:liu)bjama82 (författare)
  • Karlberg, Christian,1975-Linköpings universitet,Rehabiliteringsmedicin,Hälsouniversitetet(Swepub:liu)chrka28 (författare)
  • Syvertsson, PeterLinköpings universitet,Östergötlands Läns Landsting,Smärt- och rehabiliteringscentrum,Hälsouniversitetet (författare)
  • Elert, Jessica,1954-Linköpings universitet,Rehabiliteringsmedicin,Hälsouniversitetet(Swepub:liu)jesel87 (författare)
  • Gerdle, Björn,1953-Linköpings universitet,Östergötlands Läns Landsting,Smärt- och rehabiliteringscentrum,Hälsouniversitetet(Swepub:liu)bjoge88 (författare)
  • Linköpings universitetRehabiliteringsmedicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Electromyography & Kinesiology9:5, s. 351-3571050-64111873-5711

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy